{"product_id":"honeywell-51308095-100-tap-dcs-module","title":"Honeywell 51308095-100 TAP DCS Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51308095-100\u003c\/strong\u003e (\u003cstrong\u003e51308095-100\u003c\/strong\u003e TAP DCS Module), also cataloged as the \u003cstrong\u003e51308095-100\u003c\/strong\u003e I\/O expansion component, operates as a dedicated hardware component for signal concentration and peripheral device interfacing within distributed control system (DCS) architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51308095-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DCS module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital signal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The module architecture facilitates transparent communication with HART-compliant instrumentation, allowing for the transmission of primary process variables and secondary device diagnostics to the host control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module provides the physical interface required to bridge field-level digital bus data into the central DCS, supporting deterministic signal processing across distributed network segments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Each input and output channel incorporates galvanic decoupling to suppress common-mode electrical noise and prevent ground-loop propagation from field-side sensors or actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e Internal high-precision reference circuitry maintains signal scaling stability for analog inputs, ensuring measurement accuracy across the rated ambient temperature operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support mixed-signal configuration on the same terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Signal mapping is dependent on the specific configuration of the DCS backplane and I\/O software definition. Ensure that analog and digital signals are routed to the appropriate physical ports as defined by the system topology map.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with live insertion and removal (hot-swapping)?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping capability is dependent on the host DCS backplane revision. Consult the specific hardware installation manual for the host rack to confirm if the system architecture permits live module extraction without disrupting the control bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module into the designated slot on the DCS backplane. Secure the mechanical retention mechanisms to ensure that backplane pins are fully engaged and protected against vibration-induced displacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the cabinet’s central protective earth (PE) bus. A robust, low-impedance ground connection is mandatory to ensure the integrity of the internal galvanic isolation barriers and for electromagnetic interference immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring at the module terminal interface. Maintain a minimum separation of 150 mm between signal cabling and high-power AC or motor drive conduits to prevent inductive jitter and ensure the precision of data acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45223184007283,"sku":"51308095-100","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-12_09-53-07_e5d18ba3-142c-4f81-a473-30532ad8fe22.png?v=1783915001","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-51308095-100-tap-dcs-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}