{"product_id":"honeywell-51400700-100-dhi-module-for-lcn-network-integration","title":"Honeywell 51400700-100 | DHI Module for LCN Network Integration","description":"\u003ch2\u003eProduct Description \/ Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51400700-100 DHI is a Data Hiway Interface (DHI) card designed for Honeywell TDC 3000 and Experion PKS distributed control systems.\u003cbr\u003eIt enables seamless communication between the Local Control Network (LCN) and the Data Hiway, converting signals, buffering data, and sequencing messages efficiently.\u003cbr\u003eMoreover, this module supports high-speed, deterministic communication, ensuring reliable data exchange across controllers, operator stations, and gateways.\u003cbr\u003eIn addition, its industrial-grade PCB design provides robust performance under continuous operation in demanding process environments.\u003cbr\u003eThe 51400700-100 is essential for linking high-speed LCN modules with widely dispersed, slower Data Hiway devices.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cp\u003eProvides a reliable communication link between LCN nodes and the Data Hiway.\u003cbr\u003eSupports advanced processors including HMPU, HPK2-2, and HPK2-3 for high system compatibility.\u003cbr\u003eEnsures deterministic communication, redundancy, and enhanced system diagnostics.\u003cbr\u003eRugged PCB design guarantees continuous operation in industrial process environments.\u003cbr\u003eMaintains backward compatibility with legacy TDC 3000 nodes while improving performance.\u003c\/p\u003e\n\u003ch2\u003eTechnical Data \/ Specifications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Local Control Network (ELCN) Interface Board \/ DHI Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e51400700-100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTDC 3000 \/ Experion PKS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides LCN communication interface and protocol conversion for Data Hiway\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Processors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHMPU, HPK2-2, HPK2-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePCB circuit board, rack-mounted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVia system backplane (typically 24 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40 … +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 … 95 % non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Honeywell Eurocard PCB (~233 × 160 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 350–500 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell TDC 3000 standards, CE, UL approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of the 51400700-100 DHI card?\u003c\/strong\u003e\u003cbr\u003eIt provides a communication link between the Data Hiway and the Local Control Network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich processors are compatible with this module?\u003c\/strong\u003e\u003cbr\u003eIt supports HMPU, HPK2-2, and HPK2-3 processors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with legacy TDC 3000 systems?\u003c\/strong\u003e\u003cbr\u003eYes, it maintains backward compatibility while improving communication performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of system uses this module?\u003c\/strong\u003e\u003cbr\u003eTDC 3000 and Experion PKS distributed control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module ensure reliability?\u003c\/strong\u003e\u003cbr\u003eIts industrial-grade PCB design supports continuous operation in harsh industrial environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970809335923,"sku":"51400700-100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/424..jpg?v=1765360833","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-51400700-100-dhi-module-for-lcn-network-integration","provider":"DcsSupplier Limited","version":"1.0","type":"link"}