{"product_id":"honeywell-8c-paih54-hart-analog-input-module-series-8","title":"Honeywell 8C‑PAIH54 | HART Analog Input Module Series 8","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C‑PAIH54 (51307070‑275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel analog input module with HART capability, designed for the Experion PKS Series 8 distributed control system (DCS\/PLC). It converts analog signals from field instruments into precise digital data for process monitoring and control while simultaneously retrieving diagnostics and configuration data from HART-enabled devices.\u003c\/p\u003e\n\u003cp\u003eWidely used in oil \u0026amp; gas, petrochemical, power generation, and manufacturing industries, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C‑PAIH54 \/ 51307070‑275\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures reliable signal acquisition, high-resolution measurement, and integration with intelligent field devices for mission-critical operations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8C‑PAIH54 (51307070‑275)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels (single-ended or differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e0–5 V, 1–5 V, 0.4–2 V, 4–20 mA (with 250 Ω resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Rating\u003c\/td\u003e\n\u003ctd\u003e310 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC–60 Hz, 500 Ω imbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e19 dB @ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (internal)\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 20 mA @ 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS‑485 + HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e220 × 120 × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3–0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, IEC compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle\u003c\/td\u003e\n\u003ctd\u003eActive product, supported in Experion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970754908275,"sku":"8C-PAIH54 51307070-275","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/452._d12842a1-bebd-4c64-a125-a99f100827fe.jpg?v=1768274998","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-8c-paih54-hart-analog-input-module-series-8","provider":"DcsSupplier Limited","version":"1.0","type":"link"}