{"product_id":"honeywell-cc-gaox11-redundant-analog-output-module","title":"Honeywell CC-GAOX11 Redundant Analog Output Module","description":"\u003cp\u003eConfigured for high-reliability analog control loops in Honeywell Experion PKS C300 systems, the \u003cstrong\u003eHoneywell CC-GAOX11\u003c\/strong\u003e (\u003cstrong\u003eCC-GAOX11\u003c\/strong\u003e Analog Output Card) provides direct physical\/electrical execution. Operating as a redundant analog output module, the hardware generates calibrated 4-20 mA current signals to drive field control valves, positioners, and variable speed actuators across system channels. The dual-channel physical architecture enables real-time parallel signal generation, preventing control loop disruption during active module failover or processor updates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-GAOX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eShipping Weight 2.0 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 Series Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-powered via C300 I\/O backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Analog Output (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eRedundant Parallel Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Protocol\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART Loop Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-GAOX11 incorporates galvanic channel-to-channel isolation circuits designed to shield internal analog output conversion logic from external loop surge currents and ground potential shifts. Supporting the 4-20 mA HART loop protocol, the module allows bi-directional digital signal pass-through superimposed on the analog current loop without signal attenuation. Integrated cold junction compensation (CJC) logic support and active loop current sensing maintain continuous calibration precision across field transmitter networks and control valve circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is failover executed between redundant CC-GAOX11 modules on a shared IOTA?\u003c\/p\u003e\n\u003cp\u003eA: Failover is executed at the hardware physical layer via dedicated bus arbitration logic, switching current drive responsibility in less than 10 ms without generating bumps or dips in the output signal.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-GAOX11 module be extracted while the secondary redundant module is actively controlling the loop?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live hot-swapping provided the card ejector latches are fully disengaged to trigger soft-off backplane disengagement prior to physical removal.\u003c\/p\u003e\n\u003cp\u003eQ: What load resistance range is supported on each 4-20 mA output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each isolated channel supports standard field loop loads from 0 to 750 ohms under nominal internal loop supply conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Insertion:\u003c\/strong\u003e Guide the CC-GAOX11 module into the designated IOTA slot tracks, applying firm pressure until the top and bottom retention levers snap shut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Earth Grounding:\u003c\/strong\u003e Ensure the enclosure backplane chassis is bonded directly to the master plant protective earth (PE) system using a low-resistance copper grounding conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding Requirements:\u003c\/strong\u003e Terminate overall field instrument cable shields at the cabinet ground bar using low-impedance grounding clamps; do not ground shields at both field and cabinet ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Clearance:\u003c\/strong\u003e Route 4-20 mA analog output wiring in separate, shielded wire channels isolated by a minimum distance of 200 mm from high-voltage AC utility wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e Always wear a connected anti-static wrist strap during module handling to protect high-density analog-to-digital converter circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45371289632883,"sku":"CC-GAOX11","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CC-GAOX11_747c4851-6d88-40ba-a0be-363d46514575.png?v=1787039160","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-cc-gaox11-redundant-analog-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}