{"product_id":"honeywell-cc-taox01-output-module","title":"Honeywell CC-TAOX01 Output Module","description":"\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e is a high-density 16-channel analog output module engineered for industrial control systems. It delivers reliable 4-20 mA current signals to actuate field devices and regulate automated processes. This module features robust signal performance, including a calibrated accuracy of ±0.35% of full scale at 25°C, supporting precise control loops and dependable plant operations.\u003c\/p\u003e\n\u003ch3\u003eOutput Performance and Signal Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module provides 16 dedicated channels with a directly settable output current range spanning 0 mA and 2.9 mA to 21.1 mA. It achieves an output current linearity of ±0.05% of full scale nominal with a resolution of less than 0.05%. The DAC input-to-output response time settles to within 1% of the final value in under 80 ms.\u003c\/p\u003e\n\u003ch3\u003eLoad Capacity and Electrical Limits\u003c\/h3\u003e\n\u003cp\u003eOperating with a 24 VDC nominal supply (22 VDC to 28 VDC), the unit supports a maximum resistive load of 800 ohms and provides a maximum output compliant voltage of 16 V. The maximum open circuit voltage reaches 22 V, while output ripple remains below 100 mV peak-to-peak across a 250-ohm load at power line frequency.\u003c\/p\u003e\n\u003ch3\u003eRedundancy and Switchover Behavior\u003c\/h3\u003e\n\u003cp\u003eDesigned to support fault-tolerant architectures, the module manages signal continuity during switchover events in redundant configurations. The maximum gap of output to field during a switchover is restricted to 10 ms, ensuring minimal disruption to active control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module (IOTA Model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.35% of Full Scale (25°C) including linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.05% of Full Scale nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Temperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005% of Full Scale\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly Settable Output Current Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e800 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Compliant Voltage\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;80 ms to within 1% of final value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Output Gap\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (Redundancy only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum resistive load supported by the CC-TAOX01 module?\u003c\/p\u003e\n\u003cp\u003eA: The module supports a maximum resistive load of 800 ohms when operating with a supply voltage ranging from 22 VDC to 28 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output behavior during redundant switchover?\u003c\/p\u003e\n\u003cp\u003eA: During redundancy switchover, the maximum gap of output current to the field is limited to 10 ms to maintain loop stability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970809761907,"sku":"CC-TAOX01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CC-TAOX01_d1a7dfee-1021-416d-8e8d-ce28cb70a55d.png?v=1792405597","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-cc-taox01-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}