{"product_id":"honeywell-fc-bsdi-16uni-universal-digital-input-module","title":"Honeywell FC-BSDI-16UNI Universal Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-BSDI-16UNI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Digital Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures. This module is designed to process sixteen isolated digital channels with deterministic accuracy, making it an ideal choice for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Instrumented Systems (SIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand critical control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFC-BSDI-16UNI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Isolated Digital Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDry contact, Sourced DC, or Sinked DC voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eON-State Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≥12 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF-State Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~10 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel-to-channel and Channel-to-system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExperion PKS Series C and Safety Manager (ELD CC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features and Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety-Critical Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use in safety-instrumented functions, providing the deterministic processing required for Emergency Shutdown (ESD) and Fire \u0026amp; Gas (F\u0026amp;G) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Input Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports normally open (NO) or normally closed (NC) configurations. Its ability to accept dry and wet contacts simplifies field engineering and reduces the need for external marshalling components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel-to-channel isolation prevents a fault on one field loop from affecting others, significantly increasing total system availability and noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures continuous fault monitoring and status reporting. The module can detect internal failures and signal discrepancies, allowing for proactive maintenance before a process trip occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sophisticated isolation design shields upstream controllers from industrial electrical noise and transient voltage disturbances common in heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44960043008115,"sku":"FC-BSDI-16UNI","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-12_11-29-02.png?v=1778556704","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-fc-bsdi-16uni-universal-digital-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}