{"product_id":"honeywell-fc-tsgas-1624-input-termination-assembly","title":"Honeywell FC-TSGAS-1624 Input Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSGAS-1624\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision signal-conditioning termination board engineered for Honeywell's advanced safety and control architectures. It acts as the physical field-wiring interface for up to 16 channels of analog input, specifically designed to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0-25 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecurrent signals (common in gas detection and extended-range process transmitters) and convert them with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.1% accuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0-4V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evoltage signal.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 (common 0 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC external, 3 mA (without field loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-25 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 Ω (± 5%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Characteristics (To SAI-1620m Module):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0-4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 × 20 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 V AC \/ 300 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer \/ PN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSchurter \/ 0001.2501\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDerating Curve:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLinear from 0.5 A at 25°C to 0.35 A at 70°C module ambient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical \u0026amp; Termination:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e225 × 70 × 60 mm (8.86 × 2.76 × 2.36 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN EN Rails (TS32 \/ TS35 × 7.5), requires 226 mm rail length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax wire size 2.5 mm² (AWG 14), 7 mm strip length, 0.5 Nm tightening torque\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Terminals (A, B):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax wire size 16 mm² (AWG 8)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features and Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-accuracy (0.1%) 500-ohm resistor network ensures that critical field measurements are translated flawlessly to the DCS or Safety Manager logic solver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Hardware Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel is protected by an easily replaceable Schurter fuse. The published thermal derating curve (scaling down to 0.35A at 70°C) allows engineers to safely calculate load limits in high-temperature unconditioned cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Power Landing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated A and B power terminals accept heavy gauge (AWG 8) wire, providing a robust common power bus capable of driving all connected field transmitters without voltage drop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy separating the physical field wiring from the active computing module (SAI-1620m), techni\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44960077545587,"sku":"FC-TSGAS-1624","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-12_14-31-33_95fcdd8c-d472-4fda-9f60-bfcf91819b55.png?v=1778567662","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-fc-tsgas-1624-input-termination-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}