{"product_id":"honeywell-mc-tdod13-experion-pks-digital-output-module","title":"Honeywell MC-TDOD13 Experion PKS Digital Output Module","description":"\u003cp\u003eConfigured for high-density field actuation in Honeywell Distributed Control Systems, the \u003cstrong\u003eHoneywell MC-TDOD13\u003c\/strong\u003e (\u003cstrong\u003eMC-TDOD13\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TDOD13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Experion I\/O card profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 3.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSourced transistor (PNP), active high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (18 to 32 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current Limit\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eGreater than 250 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Marshalling \u0026amp; Loop Integrity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Isolation Barriers:\u003c\/strong\u003e Implements robust galvanic channel-to-channel isolation rated at greater than 250 VAC RMS. This design prevents field electrical faults, voltage surges, or cross-talk from migrating across adjacent loops or disrupting the Experion PKS logic backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Loop Protection:\u003c\/strong\u003e Every PNP output channel is equipped with independent short-circuit protection and auto-retry hardware. Inductive voltage spikes from switching solenoid coils or relay loops are clamped internally to maintain long-term transistor junction reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MC-TDOD13 support online module replacement (hot-swap)?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is fully hot-swappable when installed on a compatible active Experion PKS I\/O chassis. It can be replaced online without interrupting the operations of neighboring modules on the same backplane slot array.\u003c\/p\u003e\n\u003cp\u003eQ: How do the short-circuit protection and auto-retry mechanisms operate?\u003c\/p\u003e\n\u003cp\u003eA: Upon detecting a short-circuit condition on a channel (current exceeding 500 mA limit), the channel shuts down to protect the transistor. It then executes periodic auto-retry cycles to check if the fault has cleared, returning to normal operation automatically once the physical short is removed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Distribution:\u003c\/strong\u003e Ensure the external 24 VDC supply feeding the outputs is derived from a stabilized, current-limited industrial power source to prevent damage under catastrophic field wiring failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e Although the module includes internal clamping, always install flyback diodes (e.g., 1N4007) in parallel with external DC inductive loads, such as solenoids or heavy relays, to further isolate switching transient noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Maintain low-impedance bonding between the I\/O chassis assembly and the main cabinet earth ground bus to ensure the isolation barriers function at their rated specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45235449561203,"sku":"MC-TDOD13","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-29_14-13-40_9c091a30-e688-487c-bd02-cb6c8ce5ed9a.png?v=1784021884","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-mc-tdod13-experion-pks-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}