{"product_id":"honeywell-rm7898a1018-relay-module","title":"Honeywell RM7898A1018 Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell RM7898A1018\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eRM7898A1018\u003c\/strong\u003e Burner Control Unit, operates as a dedicated hardware component for safety sequence execution and valve proving within 7800 SERIES burner control systems. It mounts to a standard wiring subbase to directly manage sequence timing, pre-ignition interlocks, dynamic self-check flame detection, and automated safety valve closure testing across commercial and industrial combustion platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7898A1018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Mexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm x 127 mm x 133 mm (with Q7800A subbase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot Flame Establishing Period\u003c\/td\u003e\n\u003ctd\u003eSelectable 4 s or 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Features\u003c\/td\u003e\n\u003ctd\u003eValve Proving System (VPS), Early Spark Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Interface Features\u003c\/h3\u003e\n\u003cp\u003eThe module provides isolated digital outputs to drive dynamic self-checking ultraviolet flame detectors and safety shutoff valves via integrated hardwired relays. Internal microprocessors manage channel-to-channel isolation between low-voltage sensor inputs and line-voltage output circuits. Communication with supervisory DCS and PLC architectures is executed via an optional S7800 display module connected to the ControlBus header, ensuring system status, sequence timing, and specific fault code data are transmitted without loading the safety interlock safety loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the Integrated Valve Proving System (VPS) on the RM7898A1018?\u003c\/p\u003e\n\u003cp\u003eA: The VPS automatically tests the tight closure of safety shutoff valves prior to ignition or post-purge phases, triggering a safety lockout if valve leakage is detected.\u003c\/p\u003e\n\u003cp\u003eQ: Can the RM7898A1018 relay module be operated without plug-in accessory cards?\u003c\/p\u003e\n\u003cp\u003eA: No, the RM7898A1018 requires a plug-in flame signal amplifier, a purge timer card, and a compatible Q7800 wiring subbase to complete the functional hardware assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all line-voltage power supplies prior to installing or removing the module from the Q7800 subbase.\u003c\/li\u003e\n\u003cli\u003eVerify subbase terminal wiring aligns with the 120 VAC input and load ratings before energizing the safety loop.\u003c\/li\u003e\n\u003cli\u003eEnsure the module card-edge connector aligns straight with the subbase receptacle, applying firm hand pressure until retaining screws engage.\u003c\/li\u003e\n\u003cli\u003eSeparate high-voltage ignition leads from low-voltage signal, flame detector, and communication wiring by at least 150 mm to suppress high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45396603863155,"sku":"RM7898A1018","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/S7800A1001_6b5dabad-39f8-43a9-bf82-141bb570bf4e.png?v=1787624008","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-rm7898a1018-relay-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}