{"product_id":"honeywell-sc-ucmx02-51307198-276-controledge-rtu-communication-module","title":"Honeywell SC-UCMX02 51307198-276 ControlEdge RTU Communication Module","description":"\u003cp\u003eConfigured for high-speed data processing in remote automation networks, the \u003cstrong\u003eHoneywell SC-UCMX02\u003c\/strong\u003e (\u003cstrong\u003eHoneywell SC-UCMX02\u003c\/strong\u003e Communication Module) provides direct physical and electrical execution. This hardware assembly operates as a localized protocol gateway and I\/O aggregator within Honeywell ControlEdge RTU platforms, executing deterministic data routing without extending cycle-time latency during continuous-duty automation sequences.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSC-UCMX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlEdge RTU Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard ControlEdge RTU module mass profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact high-density chassis form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +75 deg C (-40 to +167 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eDual-voltage compliant: 24 VDC or 120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz (for alternative current operational paths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 W maximum (single unit draw profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Density\u003c\/td\u003e\n\u003ctd\u003e40 localized points (24 inputs \/ 16 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus (RTU\/TCP), DNP3 native parsing engines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Layer\u003c\/td\u003e\n\u003ctd\u003eEmbedded HART functionality (integrated hardware pass-through)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard ruggedized construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Instrumentation and DCS Communication\u003c\/h3\u003e\n\u003cp\u003eThe communication module implements localized signal processing matrices to maintain high data transmission velocity across remote telemetry links. When consolidating variable data frames from field instruments—including smart diagnostic parameters compiled via the integrated 4-20 mA HART loop protocol—the module routes the digital data straight through an on-board FSK modulation engine, eliminating the need for external secondary hardware interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the embedded HART functionality operate within the SC-UCMX02 module without auxiliary hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module's internal circuitry integrates dedicated frequency-shift keying (FSK) modems directly onto the input channels. This allows the processor to simultaneously capture the primary 4-20 mA analog process variable and poll the high-frequency secondary digital HART registers (such as calibration data or device diagnostics) over a single physical cable pair without adding execution latency.\u003c\/p\u003e\n\u003cp\u003eQ: What are the technical consequences of operating the module at its upper temperature limit of +75 deg C within a non-ventilated field enclosure?\u003c\/p\u003e\n\u003cp\u003eA: Operating continuously at +75 deg C accelerates the thermal aging profile of the internal solid-state transceivers and galvanic isolation optocouplers. While the hardware is rated for extreme environments, unmanaged internal cabinet heat accumulation can lead to increased bit-error rates during high-speed DNP3 or Modbus transmissions, potentially inducing localized processor drops or communication link timeouts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45079851827315,"sku":"SC-UCMX02 51307198-276","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-08_17-00-04_905460e6-c96d-4a60-bb54-186d2cc3a426.png?v=1780909375","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-sc-ucmx02-51307198-276-controledge-rtu-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}