{"product_id":"honeywell-tp-dikbta-100-51196694-300-industrial-keyboard","title":"Honeywell TP-DIKBTA-100 51196694-300 Industrial Keyboard","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TP-DIKBTA-100\u003c\/strong\u003e (\u003cstrong\u003e51196694-300\u003c\/strong\u003e Industrial Keyboard), also cataloged as the \u003cstrong\u003eTP-DIKBTA-100\u003c\/strong\u003e HMI component, operates as a dedicated hardware interface for operator input and cursor management within industrial process control environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTP-DIKBTA-100 (51196694-300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial console footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e While primarily an HMI input device, the integrated controller logic supports standard industrial protocols, ensuring seamless integration into DCS environments where data logging and diagnostic feedback are prioritized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The interface board architecture allows for configuration within complex network topologies, enabling the HMI to communicate diagnostic data from the operator workstation directly to field-level process controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Communication ports (RS-232\/RS-485) are electrically isolated to prevent ground potential differences from affecting data transmission integrity when the keyboard is mounted in metallic industrial enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The internal processing module maintains stable timing references and signal scaling, ensuring that operator inputs are registered without latency regardless of the environmental temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this keyboard support hot-plugging via the USB interface?\u003c\/p\u003e\n\u003cp\u003eA: USB-compliant ports support hot-plugging, but ensure the host system's HMI driver is initialized. For RS-232\/RS-485 interfaces, power-cycling or hardware reset may be required to establish communication after connection.\u003c\/p\u003e\n\u003cp\u003eQ: Are the programmable keys stored in non-volatile memory?\u003c\/p\u003e\n\u003cp\u003eA: Yes, custom key assignments are saved to the keyboard's internal non-volatile memory, ensuring configurations are retained after power loss or workstation reboots.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the unit into the console cutout using the integrated mounting hardware. Ensure the gasket seal is properly compressed to maintain the dustproof and waterproof rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the keyboard chassis to the cabinet's protective earth (PE) bus. A reliable ground is necessary to mitigate electrostatic discharge (ESD) and to maintain the integrity of the communication shield paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain proper cable management to avoid mechanical strain on the interface connectors. Route RS-232\/RS-485 cables at least 150 mm away from high-voltage AC lines to prevent induced noise and communication errors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45223160774771,"sku":"TP-DIKBTA-100 51196694-300","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-13_11-04-05.png?v=1783914800","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-tp-dikbta-100-51196694-300-industrial-keyboard","provider":"DcsSupplier Limited","version":"1.0","type":"link"}