{"product_id":"ics-triplex-t8800-1092330000-trusted-field-termination-assembly","title":"ICS TRIPLEX T8800 1092330000 Trusted Field Termination Assembly","description":"\u003cp\u003eConfigured for discrete field signal interfacing in Trusted Safety System platforms, the \u003cstrong\u003eICS Triplex T8800\u003c\/strong\u003e (\u003cstrong\u003eT8800\u003c\/strong\u003e Field Termination Assembly) provides direct physical\/electrical execution. The stainless steel hardware unit serves as the primary routing link between 2-wire digital field devices and the downstream Trusted TMR 24 VDC Digital Input Module T8403, distributing up to 40 channels of signal data per block.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8800 (Part Number 1092330000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom (GBR) \/ United States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard compact FTA mass profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C (Continuous ambient panel boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Level\u003c\/td\u003e\n\u003ctd\u003eIP67 ingress rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Capacity\u003c\/td\u003e\n\u003ctd\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU \/ TCP\/IP \/ Ethernet\/IP transmission arrays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e40 input channels per FTA module assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Interface\u003c\/td\u003e\n\u003ctd\u003e2-wire industry-standard field device terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Compatibility\u003c\/td\u003e\n\u003ctd\u003eDirectly interfaces with the Trusted T8403 Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Mounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail compatibility (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE \/ RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundant Safety Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple Modular Redundant (TMR) 2oo3 Architecture Routing:\u003c\/strong\u003e The termination assembly acts as the physical terminal bed that splits single field contact inputs into redundant signal branches. It maintains full signal path separation to feed the isolated input circuits of the companion T8403 digital card, allowing the host system to run continuous triple modular redundant (TMR) 2oo3 voting routines without individual loop latency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe State Execution Environment:\u003c\/strong\u003e Featuring an IP67-rated stainless steel enclosure, the module isolates connection terminal screws from dust, water ingress, and atmospheric corrosion. This environmental protection prevents external leakage currents from mimicking a high logic state, ensuring that true field switch openings propagate without distortion to trigger a clean fail-safe state execution in the controller registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do the 2 GB RAM and 16 GB Flash memory spaces operate on a passive-style FTA layout?\u003c\/p\u003e\n\u003cp\u003eA: The T8800 incorporates local processing intelligence to handle distributed protocol diagnostics (Modbus, TCP\/IP, Ethernet\/IP) directly at the termination boundary. The 16 GB flash and 2 GB RAM store localized event logs, communication configuration parameters, and channel identity tables independent of the main controller backplane processor.\u003c\/p\u003e\n\u003cp\u003eQ: Can field devices be rewired on the T8800 while the 24 VDC link loops are actively powered?\u003c\/p\u003e\n\u003cp\u003eA: While the rugged construction and solid-state logic withstand hot-reconnection, field wires should not be disconnected in explosive or hazardous zones due to the risk of localized electrical arcing across the 2-wire terminals. Always isolate the primary loop supply before updating terminations to ensure site safety.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Snap the stainless steel housing squarely onto a standard 35 mm metallic DIN rail inside the enclosure. Ensure the integrated grounding clips on the rear base engage tightly with the rail surface to form a continuous structural ground bond. Maintain a minimum 30 mm wire-routing clearance along the front faces to accommodate field wire terminal positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all 2-wire digital input pairs into separate low-voltage wire trays, ensuring separation from heavy three-phase AC mains and variable frequency drive output cables. Terminate individual instrument shields or cable drain wires to the designated earth terminals on the assembly base, directing transient electromagnetic noise away from the high-speed communications bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":45143427940467,"sku":"T8800 1092330000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/5ec0255a2670f401771e03ce63c12b42_aa009f36-0513-47b1-9915-0879e2c23413.png?v=1782887931","url":"https:\/\/www.dcssupplier.com\/products\/ics-triplex-t8800-1092330000-trusted-field-termination-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}