{"product_id":"ics-triplex-t9852-trusted-series-termination-assembly","title":"ICS Triplex T9852 Trusted Series Termination Assembly","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex T9852 acts as a high-integrity Digital Output Termination Assembly (TA) within the Trusted series architecture. This 8-channel, dual-commoned module facilitates the secure interface between the controller's logic and field-side actuators. It provides the physical termination points required for safety-critical signals in Triple Modular Redundant (TMR) environments. We guarantee this product is 100% Brand New, original, and ready for immediate deployment in mission-critical safety instrumented systems (SIS).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channel Dual, Commoned\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (DO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.1 x 8.4 x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrusted Chassis \/ Base Unit Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Commoned Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 Rated Systems Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBuild Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLatest Hardware\/Software Release Enhancement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe T9852 addresses specific industrial challenges regarding signal stability and system uptime. By implementing advanced filtering and dual-commoned circuitry, this module eliminates common points of failure found in standard output assemblies.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis latest release incorporates an upgraded internal filter specifically designed to neutralize noise on digital output voltage rails. This prevents the monitoring circuits from incorrectly reporting over-voltage conditions, effectively eliminating the risk of unintentional module shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s slim dimensions (13.1 x 8.4 x 4.5 cm) allow for high-density I\/O configurations within limited cabinet spaces, reducing overall infrastructure costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Fail-Safe Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-commoned design ensures that output signals maintain integrity even in electrically noisy environments, making it ideal for Turbine Control and Emergency Shutdown (ESD) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless TMR Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe T9852 interfaces directly with the Trusted T9451 Digital Output Module, providing a standardized path for signal distribution that simplifies both wiring and future diagnostic testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the T9852 handle electrical noise compared to older versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe T9852 features an improved internal filter that specifically stabilizes the voltage rails. This enhancement prevents transient noise from triggering over-voltage protection circuits, which previously caused modules to shut down unnecessarily.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this termination assembly compatible with single-channel modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the T9852 is specifically designed as an 8-channel dual-commoned termination assembly. For simplex applications, you should utilize the T9851 variant. Always verify your system architecture (Simplex vs. Dual\/TMR) before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary applications for the T9852?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers primarily utilize the T9852 in high-availability solutions such as Boiler Management Systems (BMS), Compressor Control, Fire \u0026amp; Gas (F\u0026amp;G) systems, and Emergency Parking Systems (ESD).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I inspect the T9852 before final shipping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We allow local pickup and inspection appointments for all ordered items. Alternatively, we provide worldwide express shipping via DHL, TNT, and FedEx to ensure the material reaches your site within your project's timeframe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":42970316177523,"sku":"T9852","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/67.jpg?v=1775800734","url":"https:\/\/www.dcssupplier.com\/products\/ics-triplex-t9852-trusted-series-termination-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}