{"product_id":"innpm12-abb-bailey-network-processing-unit-for-infi90-systems","title":"INNPM12 ABB Bailey Network Processing Unit for Infi90 Systems","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INNPM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary communication intelligence for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBailey INFI 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system. This Network Process Module manages high-level data exchange between the local Inf-Net communication ring and the control modules within a specific rack. It handles complex message routing, data buffering, and protocol translation, ensuring that critical process information reaches the operator console without latency. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support the long-term maintenance of your legacy automation assets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB \/ Bailey\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINNPM12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINFI 90 \/ Network 90\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Processing Unit (NPU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC @ 2.5A (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNET \/ Plant Loop \/ Infi-Net\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 70°C (32 to 158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard INFI 90 Module Mounting Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Legacy Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe INNPM12 integrates directly into existing INFI 90 cabinets. It provides a stable communication bridge that allows older control hardware to communicate with modern HMI interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module utilizes advanced onboard processing to filter and prioritize process data. By reducing \"bus noise\" and managing packet traffic, the INNPM12 prevents network congestion during high-alarm process events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB designed the INNPM12 to withstand the harsh electromagnetic interference (EMI) found in power generation and chemical processing environments. The multilayer PCB design protects signal integrity from external noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperators can replace the INNPM12 while the rack remains powered (following proper safety protocols), minimizing process disruption and facilitating rapid system recovery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the INNPM12 require specific firmware to match my existing INNPM01\/11 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe INNPM12 generally supports downward compatibility; however, we recommend verifying your current system software version. Our technical team can help identify the correct firmware revision for your specific DCS environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with the older Network 90 hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The INNPM12 maintains compatibility with most legacy Bailey Network 90 cabinets, provided you use the appropriate termination units (TU) and cables designed for the INFI 90 transition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected lead time for a brand new INNPM12?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe typically maintain stock of the INNPM12. Standard shipping via DHL\/FedEx usually takes 2-3 business days. For urgent plant-down situations, please contact us for immediate dispatch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module include the rear termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis listing covers the INNPM12 module itself. Termination units (such as the NTIM12) are separate components. If you require the complete assembly, please specify the TU part number in your inquiry.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42974857429107,"sku":"INNPM12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/447._13d6f15c-4a01-459f-9cbb-648eb6d81c0f.jpg?v=1776044044","url":"https:\/\/www.dcssupplier.com\/products\/innpm12-abb-bailey-network-processing-unit-for-infi90-systems","provider":"DcsSupplier Limited","version":"1.0","type":"link"}