{"product_id":"safety-modules-schneider-electric-tsxpay262","title":"Safety Modules | Schneider Electric TSXPAY262","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003eTSXPAY262\u003c\/strong\u003e is a standard-format Preventa safety module engineered for integration into the Modicon Premium automation platform. Operating on a 24 VDC nominal supply voltage, the module serves as a central safety interface for emergency stop and machine interlock monitoring. It combines dedicated discrete safety inputs, logic acquisition, and robust volt-free safety relay outputs to ensure high-integrity functional safety compliance up to SIL 3 and ISO 13849-1 Category 4.\u003c\/p\u003e\n\u003ch3\u003eSafety Input Architecture and Circuit Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe module accommodates 12 discrete inputs for emergency stop buttons or limit switches conforming to IEC 61131 Type 1, operating on positive logic. Auxiliary input channels are dedicated to single\/double contact selection, feedback loop reading, and reset push-button monitoring. Internal safety acquisition continuously validates enable inputs, output control states, and 24 VDC external supply health to ensure immediate fault detection.\u003c\/p\u003e\n\u003ch3\u003eRelay Output Performance and Switching Capacity\u003c\/h3\u003e\n\u003cp\u003eOutput execution is handled by four normally open (NO) gold-plated, volt-free safety relay contacts designed for high switching reliability. These outputs support operating voltages up to 250 VAC or 127 VDC, delivering a conventional thermal current of 2.5 A and rapid response times under 12 ms. Protection requires external 4 A gG fuses on the safety relay circuits, alongside 1 A gG fuses on the module power supply.\u003c\/p\u003e\n\u003ch3\u003eElectrical Connections and System Diagnostics\u003c\/h3\u003e\n\u003cp\u003ePhysical interfacing utilizes a 44-pin SUB-D connector for safety circuit signals and a removable 6-pin screw terminal block for safety output wiring (supporting wire cross-sections up to 2.5 mm²). Real-time status evaluation is facilitated by 28 local LED indicators covering safety loop diagnostic states. System power consumption remains low, taking under 150 mA at 5 VDC from the backplane and no more than 200 mA from the 24 VDC external supply.\u003c\/p\u003e\n\u003ch3\u003eParameter | Specification\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXPAY262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePreventa Safety Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2…30 V DC limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 150 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 200 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Outputs\u003c\/td\u003e\n\u003ctd\u003e4 NO safety relay (gold-plated, volt-free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Enclosed Thermal Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Current\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Safety Inputs\u003c\/td\u003e\n\u003ctd\u003e12 emergency stop \/ limit switch inputs (IEC 61131 Type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Safety Inputs\u003c\/td\u003e\n\u003ctd\u003e1 contact selection, 1 feedback loop, 2 reset PB monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e28 LEDs for diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e1 x 44-pin SUB-D connector, 1 x 6-pin removable screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0…40 deg C (without fan), 0…60 deg C (with fan module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25…70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (conforming to IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.49 kg (1.08 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFunctional Safety Standards and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e ISO 13849-1 Category 4, IEC 61508 SIL 3, EN\/IEC 60204-1, ISO 13850, EN 954\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications:\u003c\/strong\u003e CSA, UL, BG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What size external fuses are required to protect the TSXPAY262 safety output circuits? A: The safety relay outputs require external short-circuit protection using 4 A gG fuses conforming to IEC 947-5-1.\u003c\/p\u003e\n\u003cp\u003eQ: What are the wire cross-section requirements for the safety output terminal block? A: The removable 6-pin terminal block supports conductors from 0.2 to 2.5 mm² without cable ends, or up to 1.5 mm² with cable ends.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TSXPAY262 operate in high-temperature environments above 40 deg C? A: Yes, while the standard operating temperature range is 0 to 40 deg C without external cooling, it can operate up to 60 deg C when installed with a fan module.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67100809691251,"sku":"TSXPAY262","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXPSY2600M_3.png?v=1793696956","url":"https:\/\/www.dcssupplier.com\/products\/safety-modules-schneider-electric-tsxpay262","provider":"DcsSupplier Limited","version":"1.0","type":"link"}