{"product_id":"schneider-bmexbp0400-modicon-x80-ethernet-backplane","title":"Schneider BMEXBP0400 Modicon X80 Ethernet Backplane","description":"\u003cp\u003eConfigured for mechanical module hosting and dual-bus signal distribution in enterprise automation platforms, the \u003cstrong\u003eSchneider Electric BMEXBP0400\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMEXBP0400\u003c\/strong\u003e Modicon X80 Rack, provides direct physical\/electrical execution. This 4-slot backplane features an integrated dual-bus architecture supporting both standard X-bus serial communication and high-speed Ethernet infrastructure across the chassis plane to interconnect processing cores, power modules, and I\/O assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEXBP0400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance (FRA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.705 kg (Net backplane) \/ 743.000 g (Packaged mass unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.600 cm x 15.300 cm x 32.500 cm (Packaged volume dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Standard continuous operation parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e162 mW at 3.3 V DC \/ 2.8 W at 24 V DC (Internal rail draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e49 mA at 3.3 V DC \/ 118 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Configuration\u003c\/td\u003e\n\u003ctd\u003e4 slots supporting concurrent X-bus and Ethernet connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eBMX\/BME Processors, BMXCPS Power Supplies, Modicon X80 I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capability\u003c\/td\u003e\n\u003ctd\u003e1 connector slot dedicated to XBE expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing Methods\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetric DIN rail clips \/ Panel M6 screws (4.32 to 6.35 mm diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ Relative humidity: 5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReliability Profile\u003c\/td\u003e\n\u003ctd\u003eMTBF 1,588,025 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectives\u003c\/td\u003e\n\u003ctd\u003e2014\/35\/EU (Low Voltage), 2014\/30\/EU (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSchneider Electric Deterministic Network Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Backplane Routing:\u003c\/strong\u003e The backplane architecture integrates dedicated Ethernet trace lines alongside traditional X-bus paths. This setup enables BME processors to stream deterministic EtherNet\/IP or Profinet data frames straight through the rack assembly to compatible network and high-density I\/O modules without introducing protocol conversion latencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility Matrix Protection:\u003c\/strong\u003e The integrated electronic traces maintain uniform impedance across all 4 module slots. This structural design secures synchronous logic processing and helps prevent communication drops or packet corruption during high-speed firmware flash upgrades of plugged-in expansion cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific hot-swap limitations when inserting modules into the BMEXBP0400 backplane?\u003c\/p\u003e\n\u003cp\u003eA: Standard Modicon X80 I\/O modules can be hot-swapped under live backplane power conditions. However, the central BMX\/BME processor module and the BMXCPS power supply unit are strictly excluded from live extraction; removing them while energized will disrupt the internal 3.3 V and 24 V DC distribution rails, dropping active control loops.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical rack layout expanded if more than 4 slots are required by the application?\u003c\/p\u003e\n\u003cp\u003eA: The backplane contains 1 dedicated expansion module connector slot for an XBE expansion card. Interfacing an XBE module allows the internal X-bus serial communications to transition across an extension cable to a secondary Modicon X80 rack chassis without breaking bus integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Mount the backplane chassis horizontally onto a grounded, symmetric 35 mm DIN rail using the integrated locking clips, or bolt it flat to a rigid mounting plate using four M6 structural screws. Ensure that adjacent cable ducts preserve a minimum clearance boundary of 50 mm around the frame to allow natural thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all low-voltage Ethernet network paths and analog sensor lines through wiring tracks isolated away from high-potential AC lines or inductive motor starter wiring. Ensure the backplane metallic ground clip establishes a direct, metal-on-metal connection to a clean panel frame or master enclosure copper earth bar to safely sink high-energy electrostatic discharge transients.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":45141486272627,"sku":"BMEXBP0400","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-05_09-16-20_8fd7a92e-7f5d-41d2-b077-99b0226bf35d.png?v=1782805980","url":"https:\/\/www.dcssupplier.com\/products\/schneider-bmexbp0400-modicon-x80-ethernet-backplane","provider":"DcsSupplier Limited","version":"1.0","type":"link"}