{"product_id":"schneider-bmxami0410-modicon-x80-analog-output-module","title":"Schneider BMXAMI0410 Modicon X80 Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider BMXAMI0410\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXAMI0410\u003c\/strong\u003e analog output module, operates as a dedicated hardware component for multi-channel voltage and current signal conversion within Modicon X80 automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance (FR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.5 cm x 11.0 cm x 5.5 cm (Package 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W typical at 24 VDC, 0.45 W typical at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Number\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Type\u003c\/td\u003e\n\u003ctd\u003eCurrent (0-20 mA, 4-20 mA), Voltage (+\/- 10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 VDC between channels and ground \/ bus, 750 VDC between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider BMXAMI0410\u003c\/strong\u003e interfaces seamlessly with high-speed deterministic backplane architectures inside the Modicon X80 ecosystem. Utilizing channel-to-channel and channel-to-bus galvanic isolation rated up to 1400 VDC, the module suppresses common-mode disturbances up to 100 dB and guarantees minimum crosstalk attenuation of 80 dB. The internal 15-bit plus sign resolution DAC configuration ensures precise output delivery across voltage and current loops, backed by rapid conversion cycles of under 1 ms and independent open\/short-circuit diagnostic reporting for every channel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXAMI0410 support live insertion and removal (hot-swapping) in an active Modicon X80 rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Modicon X80 modules are designed for hot-swapping in non-hazardous industrial locations, allowing replacement without powering down the entire backplane rack.\u003c\/p\u003e\n\u003cp\u003eQ: How is power supplied to the module during standard operation?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power internally via the rack backplane, requiring both 3.3 VDC and 24 VDC supply inputs from the rack power distribution bus.\u003c\/p\u003e\n\u003cp\u003eQ: What fallback behavior occurs if communication with the main CPU is lost?\u003c\/p\u003e\n\u003cp\u003eA: Fallback behavior is fully configurable or can use predefined safe states, allowing individual channels to hold their last value, switch to a fallback value, or disable output execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Inspection:\u003c\/strong\u003e Inspect the rack slot connector pins for debris or bending before inserting the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Engagement:\u003c\/strong\u003e Slide the module along the guide rails until the top and bottom locking tabs click securely into the X80 rack chassis frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminations:\u003c\/strong\u003e Connect field loop wiring to the 20-way removable terminal block connector, ensuring proper wire gauge and shield grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Verification:\u003c\/strong\u003e Power on the rack and verify that the green RUN LED illuminates steady and individual channel diagnostic LEDs remain active without error indications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":66852648321139,"sku":"BMXAMI0410","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/BMXAMI0410_Cocoai_75fb6784-dfe7-424b-ad76-4fc42e977414.jpg?v=1791872508","url":"https:\/\/www.dcssupplier.com\/products\/schneider-bmxami0410-modicon-x80-analog-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}