{"product_id":"schneider-electric-140xcp90000-event-recording-module","title":"Schneider Electric 140XCP90000 Event Recording Module","description":"\u003cp\u003eThe \u003cstrong\u003e140XCP90000\u003c\/strong\u003e is a multifunctional input module for the Modicon Quantum Automation Platform, designed to monitor 32 discrete input signals and record their status changes with time and date stamps. It includes a dedicated 24 V clock signal input and uses the DCF77 time synchronization protocol. Its event logging function supports status monitoring at 500 Hz, making it suitable for applications requiring time-correlated recording of discrete signal events.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Event Recording\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides 32 discrete processing inputs arranged in two groups of 16 channels, together with one dedicated 24 V clock signal input. The processing inputs support external signal voltages from 24 V to 125 V DC, allowing the module to monitor discrete control signals across different voltage levels.\u003c\/p\u003e\n\u003cp\u003eIts event recording function captures input status changes with associated date and time information. The specified status logging rate is 500 Hz. The DCF77 protocol provides the time synchronization reference, which is important when correlating recorded events with other control system data.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Processing and Input Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports configurable no-rebound filtering from 0 to 255 ms. This setting allows input transitions to be filtered to reduce unwanted state changes caused by contact bounce or electrical disturbances. Input status can also be configured for reverse logic, depending on the required signal interpretation.\u003c\/p\u003e\n\u003cp\u003eOptocoupler isolation is provided for the clock signal input, with optical isolation between the two input channel groups. This arrangement separates the input groups electrically and supports reliable discrete signal acquisition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connections and Status Indication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eField wiring connects through a 40-terminal screw terminal block. The specified maximum input cable lengths are less than 600 m for shielded cables and less than 400 m for unshielded cables.\u003c\/p\u003e\n\u003cp\u003eThe front panel provides 32 input status LEDs, along with three additional indicators: a green Active LED for bus communication, a green R LED for successful self-test and module readiness, and a red F LED for fault indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140XCP90000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMultifunctional Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Event Recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Processing Inputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Signal Input\u003c\/td\u003e\n\u003ctd\u003e1 at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e2 groups of 16 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Logging Rate\u003c\/td\u003e\n\u003ctd\u003e500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization Protocol\u003c\/td\u003e\n\u003ctd\u003eDCF77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V at 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V at 2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V at 2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V at 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Signal Input Collection Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Signal Input Current\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo-Rebound Filtering\u003c\/td\u003e\n\u003ctd\u003eConfigurable from 0 to 255 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Status Logic\u003c\/td\u003e\n\u003ctd\u003eReverse configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eOptocoupler isolation for clock input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Group Isolation\u003c\/td\u003e\n\u003ctd\u003eOptical coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W (input processing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA at 5 V DC on the bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.07 mA at 24 V DC in the 140XCP90000 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Current\u003c\/td\u003e\n\u003ctd\u003e3 mA at 24 to 125 V DC per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e40-terminal screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielded Input Cable Length\u003c\/td\u003e\n\u003ctd\u003eLess than 600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnshielded Input Cable Length\u003c\/td\u003e\n\u003ctd\u003eLess than 400 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Indicator\u003c\/td\u003e\n\u003ctd\u003e1 green Active LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Ready Indicator\u003c\/td\u003e\n\u003ctd\u003e1 green R LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Indicator\u003c\/td\u003e\n\u003ctd\u003e1 red F LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Status Indicators\u003c\/td\u003e\n\u003ctd\u003e32 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge Resistance\u003c\/td\u003e\n\u003ctd\u003e4 kV contact; 8 kV air discharge, IEC 801-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Field Resistance\u003c\/td\u003e\n\u003ctd\u003e10 V\/m, 80 to 2000 MHz, IEC 801-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL 508, CSA Class 1 Division 2, UL, LR, C-Tick, GOST, Merchant Ship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible Software\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified compatible software includes Concept and Union Pro. These software environments are relevant when configuring the module and integrating its input event information into the Modicon Quantum control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many discrete input signals can the 140XCP90000 monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 32 processing inputs arranged in two groups of 16, plus one dedicated 24 V clock signal input. The clock input serves a separate timing function and is not included in the 32 processing inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the DCF77 protocol?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: DCF77 provides the time synchronization reference used for date and time stamping of recorded input events. This allows discrete signal changes to be associated with a common time reference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the input filtering time be adjusted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The no-rebound filtering time is configurable from 0 to 255 ms. The setting should be selected according to the input signal characteristics and the required event detection response.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67189036253299,"sku":"140XCP90000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/140XCP90000_Cocoai_8858c3e1-4dfd-4d98-a6dd-e234c6e6a441.jpg?v=1794555153","url":"https:\/\/www.dcssupplier.com\/products\/schneider-electric-140xcp90000-event-recording-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}