{"product_id":"schneider-electric-tsxdmy28fk-discrete-i-o-module","title":"Schneider Electric TSXDMY28FK Discrete I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eTSXDMY28FK\u003c\/strong\u003e is a 28-point discrete I\/O module for the Modicon Premium Automation platform from Schneider Electric. It combines 16 fast discrete inputs and 12 solid-state discrete outputs in a single standard-format module. The module operates with 24 VDC field signals and supports 2-wire and 3-wire proximity sensors, configurable input filtering, and electronic output protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides 16 current-sinking fast inputs with IEC 1131-2 Type 1 characteristics and positive input logic. The 24 VDC input circuits accept signals from compatible 2-wire or 3-wire proximity sensors. Input filtering can be configured from 0.1 to 7.5 ms, with a default setting of 4 ms.\u003c\/p\u003e\n\u003cp\u003eThe guaranteed signal thresholds define the valid ON and OFF states. The module also supports input paralleling, allowing multiple input circuits to be connected in parallel where the application wiring and sensor specifications permit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSolid-State Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 12 discrete outputs use solid-state switching, with a nominal output voltage of 24 VDC. Each channel supports up to 0.5 A, while the total module output current is limited to 4 A. The output response time is 0.6 ms, making the module suitable for applications requiring relatively fast discrete switching.\u003c\/p\u003e\n\u003cp\u003eOutput protection includes a Transil diode for overvoltage protection and a reverse diode for reverse-polarity protection. The residual voltage in the ON state is 1.2 V, while the maximum leakage current in the OFF state is 1 mA. These characteristics should be considered when selecting connected loads, particularly low-current electronic devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connection and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXDMY28FK uses two HE-10 connectors for field signal connections. Its internal supply requirements are 300 mA at 5 VDC and 75 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003ePower dissipation is specified as 1.2 W plus 0.1 W for each input in the ON state. The output circuits also require consideration of the total module current limit when several channels operate simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Operating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is specified for operation at ambient temperatures from 0 to 60 deg C and storage temperatures from -25 to 70 deg C. Relative humidity must remain between 5% and 95%, without condensation.\u003c\/p\u003e\n\u003cp\u003eAt 60 deg C, the specified derating limits are 60% of inputs in the ON state for fast-input operation and 60% of the maximum module output current for solid-state outputs. The module is specified for installation at altitudes up to 2,000 m.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDMY28FK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Discrete I\/O\u003c\/td\u003e\n\u003ctd\u003e28 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent-sinking fast inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 1131-2 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e3.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed Voltage State 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed Current State 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed Voltage State 0\u003c\/td\u003e\n\u003ctd\u003e10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Module\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage\u003c\/td\u003e\n\u003ctd\u003e1.2 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Impedance\u003c\/td\u003e\n\u003ctd\u003e48 W (as specified in source data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tungsten Load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e0.6 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI^2 Hz (as specified in source data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eTransil diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eReverse diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreactuator Voltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e2 x HE-10 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 5 VDC\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.2 W + 0.1 W per input at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,500 V AC, 50\/60 Hz for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDerating at 60 deg C\u003c\/td\u003e\n\u003ctd\u003e60% input ON-state capacity; 60% maximum module output current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110896404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturnability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input and output channels does the TSXDMY28FK provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 28 discrete I\/O points, comprising 16 fast discrete inputs and 12 solid-state outputs. Both input and output circuits use 24 VDC field signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What sensors are compatible with the TSXDMY28FK inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The input circuits support 2-wire and 3-wire proximity sensors. They use current-sinking input characteristics with positive logic and a configurable filter time of 0.1 to 7.5 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output current can each channel support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each solid-state output supports up to 0.5 A, subject to a maximum total module output current of 4 A. At 60 deg C, the specified derating factor limits the module to 60% of its maximum output current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67246135869555,"sku":"TSXDMY28FK","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXDEY64D2K_Cocoai_46dde609-0afc-4cab-a0a0-a4ca8939c512.jpg?v=1794990492","url":"https:\/\/www.dcssupplier.com\/products\/schneider-electric-tsxdmy28fk-discrete-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}