{"product_id":"schneider-electric-tsxdsy08s5-modicon-premium-discrete-output-module","title":"Schneider Electric TSXDSY08S5 Modicon Premium Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eTSXDSY08S5\u003c\/strong\u003e is an 8-channel discrete output module for the Schneider Electric Modicon Premium Automation platform. It provides Triac-protected AC outputs rated for 48...240 V AC, with a maximum current of 2 A per channel and 12 A per module. Integrated fast-blow fuses provide overload and short-circuit protection, while Ge-MOV devices protect the outputs against overvoltage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides eight AC output channels for controlling external electrical loads. Its Triac output design supports AC switching, with activation and deactivation response times of less than 10 ms.\u003c\/p\u003e\n\u003cp\u003eEach channel supports up to 2 A, subject to the module's maximum total current rating of 12 A. The integrated 5 A fast-blow fuses provide overload and short-circuit protection, while Ge-MOV components provide output overvoltage protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified output voltage is 48...240 V AC, with an EN\/IEC 61131-2 range of 41...264 V. The module draws 125 mA from the 5 V DC supply. Its power dissipation is calculated using the following formula:\u003c\/p\u003e\n\u003cp\u003e\\[ P = 0.5 + 1 \\times N \\times I \\]\u003c\/p\u003e\n\u003cp\u003eWhere N is the number of outputs and I is the module current in amperes, according to the supplied specification. The screw terminal block provides the electrical connection for field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXDSY08S5 uses a standard module format and has an IP20 protection rating. It is specified for operation at ambient temperatures from 0 to 60 deg C, with relative humidity of 10 to 95% without condensation.\u003c\/p\u003e\n\u003cp\u003eThe module supports storage temperatures from -25 to 70 deg C and operating altitudes up to 2000 m. Its TC protective treatment and pollution degree 2 rating are specified for the stated environmental conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSY08S5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Platform\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTriac protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e48...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range (EN\/IEC 61131-2)\u003c\/td\u003e\n\u003ctd\u003e41...264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivation Response Time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeactivation Response Time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eGe-MOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overload Protection\u003c\/td\u003e\n\u003ctd\u003e5 A integrated fast-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e5 A integrated fast-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2000 V AC, 50\/60 Hz, 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.5 W + 1 W x No. of outputs x current per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e10...95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eBV, RMRS, DNV, RINA, LR, GL, ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, UL 508, CSA C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Standards and Directives\u003c\/td\u003e\n\u003ctd\u003e73\/23\/EEC, 89\/336\/EEC, 92\/31\/EEC, 93\/68\/EEC; CSA C22.2 No. 213 Class I Division 2 Groups A, B, C and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110725827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Quantity (Unit 1)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (Unit 1)\u003c\/td\u003e\n\u003ctd\u003e5.5 x 18.0 x 26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight (Unit 1)\u003c\/td\u003e\n\u003ctd\u003e609 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Quantity (Unit 2)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (Unit 2)\u003c\/td\u003e\n\u003ctd\u003e30 x 30 x 40 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight (Unit 2)\u003c\/td\u003e\n\u003ctd\u003e4.872 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturnability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output channels does the TSXDSY08S5 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TSXDSY08S5 provides eight Triac-protected AC output channels. Each channel supports a maximum current of 2 A, while the total current across the module must not exceed 12 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection features are integrated into the TSXDSY08S5?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module includes Ge-MOV output overvoltage protection and integrated 5 A fast-blow fuses for overload and short-circuit protection. These features provide electrical protection at the output stage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TSXDSY08S5 switch DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified outputs are designed for AC operation, with a rated voltage range of 48...240 V AC. The supplied specifications do not establish DC load compatibility.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67257648087155,"sku":"TSXDSY08S5","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXDEY16A4_Cocoai_7cc50229-9906-45c2-88e3-bf78b8354555.jpg?v=1795076063","url":"https:\/\/www.dcssupplier.com\/products\/schneider-electric-tsxdsy08s5-modicon-premium-discrete-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}