{"product_id":"schneider-electric-tsxdsy08t3-output-module","title":"Schneider Electric TSXDSY08T3 Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eTSXDSY08T31\u003c\/strong\u003e is an 8-channel solid-state protected discrete output module for the Modicon Premium Automation Platform. It switches 48 VDC loads with a fast 0.2 ms response time and connects field wiring via a screw terminal block. Built-in transil diodes, reverse-mounted protection diodes, and electronic overload and short-circuit tripping help safeguard output circuits during operation.\u003c\/p\u003e\n\u003ch3\u003eOutput Circuits and Protection\u003c\/h3\u003e\n\u003cp\u003eEach channel switches a 48 VDC nominal output conforming to EN\/IEC 61131-2 across 38...60 V, supporting a nominal 1 A discrete output current and a 1.25 A per-channel rating, while total module current is capped at 7 A. A 34 V front drive voltage detection threshold and a minimum load impedance of 48 ohm define valid drive conditions.\u003c\/p\u003e\n\u003cp\u003eWhen switched off, maximum leakage current is 1 mA, and residual voltage reaches up to 1 V. Inductive switching frequency is limited by 0.5\/LI^2 Hz, while overload and short-circuit protection use electronic tripping upon reactivation alongside transil overvoltage diodes and reverse polarity protection.\u003c\/p\u003e\n\u003ch3\u003ePower and Mechanical Ratings\u003c\/h3\u003e\n\u003cp\u003eInternal logic draws 55 mA at 5 VDC, and total power consumption follows (2.2 W + 0.55 W x number of outputs x current in each module). The standard-format module has a net weight of 0.32 kg and an IP20 ingress protection rating for pollution degree 2 environments.\u003c\/p\u003e\n\u003cp\u003eIt operates from 0...60 deg C and up to 2000 m altitude, with storage rated from -25...70 deg C and TC protective treatment. Dielectric strength is rated at 1500 V at 50\/60 Hz for 60 s, and insulation resistance exceeds 10 Mohm at 500 V.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSY08T31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eDiscrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Category\u003c\/td\u003e\n\u003ctd\u003eSolid State Protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC (conforms to EN\/IEC 61131-2, 38...60 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Per Channel\u003c\/td\u003e\n\u003ctd\u003e1.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Per Module\u003c\/td\u003e\n\u003ctd\u003e7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Drive Voltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e34 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Impedance\u003c\/td\u003e\n\u003ctd\u003e48 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA (in 0 state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage (Ures)\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI^2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eUsing transil diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eReverse mounting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overload Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic tripping upon reactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic tripping upon reactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e55 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e(2.2 W + 0.55 W x number of outputs x current in each module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V 50\/60 Hz 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 Mohm 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection Level\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Level\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Air Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10...95% no condensation (operation); 5...95% no condensation (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Height\u003c\/td\u003e\n\u003ctd\u003e0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2; UL 508; CSA C22.2 No 142; CSA C22.2 No 213 Category I Department 2 Groups A, B, C, D; 73\/23\/EEC; 89\/336\/EEC; 92\/31\/EEC; 93\/68\/EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certification\u003c\/td\u003e\n\u003ctd\u003eGL, RMRS, LR, BV, RINA, ABS, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMark\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Weight\u003c\/td\u003e\n\u003ctd\u003e529.0 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Dimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e26.0 cm x 18.0 cm x 6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How much total current can the TSXDSY08T31 supply across all 8 channels? A: Although discrete output current is 1 A and per-channel current is rated up to 1.25 A, maximum current per module is 7 A. Total load current across the 8 outputs must stay within the 7 A module limit and respect the 48 ohm minimum load impedance.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TSXDSY08T31 handle overloads, short circuits, and voltage spikes? A: It provides electronic tripping upon reactivation for overload and short-circuit conditions, paired with transil diodes for output overvoltage protection and a reverse-mounted diode for reverse polarity protection. Field drive detection also includes a 34 V threshold.\u003c\/p\u003e\n\u003cp\u003eQ: What operating limits apply to temperature, altitude, and humidity? A: Operating ambient air temperature is 0...60 deg C up to a working height of 2000 m, with relative humidity from 10...95% without condensation. Storage is rated from -25...70 deg C at 5...95% relative humidity without condensation.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67257992085619,"sku":"TSXDSY08T31","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXDSY16S52_b23d898d-fc65-4772-a031-695cafcc6769.png?v=1795080197","url":"https:\/\/www.dcssupplier.com\/products\/schneider-electric-tsxdsy08t3-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}