{"product_id":"schneider-tsxmap1074-modicon-tsx-series-7-communication-module","title":"Schneider TSXMAP1074 Modicon TSX Series 7 Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSXMAP1074\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXMAP1074\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for MAPWAY network coordination within Modicon TSX Series 7 automation platforms. The hardware establishes a physical and electrical interface between the parallel backplane bus of the host controller and a MAPWAY local area network token-bus infrastructure, executing serial data packet distribution across peer-to-peer processor configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXMAP1074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (Telemecanique)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon TSX Series 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance (FRA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.51 lbs (1.14 kg net module mass profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard multi-slot TSX Series 7 rack module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Continuous ambient panel boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-45 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via internal 5 VDC backplane bus lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Architecture\u003c\/td\u003e\n\u003ctd\u003eMAPWAY proprietary industrial token-bus local area network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connection\u003c\/td\u003e\n\u003ctd\u003eFront-mounted multi-pin network port connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Capacity\u003c\/td\u003e\n\u003ctd\u003eStandard fixed MAPWAY transmission speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon Industrial Control Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Alignment:\u003c\/strong\u003e The communication interface card interfaces directly with legacy TSX Series 7 backplane tracks, coordinating synchronized cyclical register transfers. It continuously exchanges process variables and station indicators with the central processing unit at native bus velocity without altering the fixed background I\/O scan sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Gateway Capacity:\u003c\/strong\u003e The module isolates the legacy deterministic MAPWAY segment tokens from standard data lines. While acting as a local peer routing agent, it provides a structured memory image that can be mapped upward into bridging modules connected to plant-wide Profinet \/ EtherNet\/IP deterministic networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TSXMAP1074 support active hot-swapping during standard processor operations?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical and electrical bus architecture of TSX Series 7 backplane subracks lacks hot-swap capabilities. Removing or seating this module while the system frame is energized will cause critical bus voltage disruptions, drop communication rings, and induce an unrecoverable system fault on the main processor.\u003c\/p\u003e\n\u003cp\u003eQ: How are network node configurations and protocol arbitration states maintained on this module?\u003c\/p\u003e\n\u003cp\u003eA: Protocol parameters, station addressing registers, and Master\/Slave roles are designated via configuration software utilities and stored directly within the non-volatile internal firmware tables of the card. These settings remain locked in local memory independent of external power states or backplane bus drops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Lower the 2.51 lbs housing directly onto the matching slot tracks of the TSX Series 7 subrack chassis. Ensure the rear multi-pin interfaces match the backplane grid perfectly before pressing the module backward into the internal connector frame, and secure all manual alignment thumbscrews to ground the front panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all serial communication links and network drops through independent, metallic, enclosed wire channels separated from three-phase AC power circuits or switching inductive load lines. Termination shields must be bonded directly to a low-impedance master earth rail at a single location to negate electromagnetic noise injection across data lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45143429480563,"sku":"TSXMAP1074","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-30_16-06-22_35fe40a3-f650-403d-a817-b56ddb9cf2ca.png?v=1782875959","url":"https:\/\/www.dcssupplier.com\/products\/schneider-tsxmap1074-modicon-tsx-series-7-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}