{"product_id":"schneider-tsxpsy2600m-modicon-premium-power-supply-module","title":"Schneider TSXPSY2600M Modicon Premium Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSXPSY2600M\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXPSY2600M\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for localized AC-to-DC rectification and backplane power distribution within Schneider Electric Modicon Premium automation platforms. The hardware transforms broad-range alternating input line potential into stabilized direct current voltage tracks, supplying the internal electrical bias required to energize adjacent central processing units, communication interfaces, and peripheral I\/O modules across the subrack chassis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXPSY2600M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance (FRA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.06 lbs (0.48 kg net mass profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot Modicon Premium rack footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Continuous ambient panel boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC nominal range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency Range\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e26 W maximum backplane power delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Rating\u003c\/td\u003e\n\u003ctd\u003e300 mA maximum primary current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer 12\/01\/2020 (Replaced by BMXCPS2000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon Premium Automation Framework\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Power Distribution Efficiency:\u003c\/strong\u003e The internal switching regulation matrix processes incoming 100-240 VAC power to feed highly stable 5 VDC and 24 VDC rails across the local subrack. By maintaining rigid voltage regulation limits under changing load steps, the power supply sustains uninterrupted backplane bus communication velocity and logic tracking states across adjacent slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling System Stabilization:\u003c\/strong\u003e The 26 W power footprint provides the necessary energy to support heavy I\/O density scaling configurations within a single chassis. Onboard galvanic and optical separation layers isolate the sensitive internal backplane computing plane from external main AC line voltage anomalies, transients, and switching noise fields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the TSXPSY2600M power supply module be unseated or hot-swapped while the primary AC mains line is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical chassis interlock guidelines dictate that the primary 100-240 VAC input line must be completely isolated before extracting or inserting the module. Pulling this component from a live subrack will break active high-current pins, generate electrical arcing, and cause an immediate power drop that could corrupt data in the connected processor.\u003c\/p\u003e\n\u003cp\u003eQ: How does the power supply handle brief voltage sags or micro-breaks on the incoming 50\/60 Hz line?\u003c\/p\u003e\n\u003cp\u003eA: The module is equipped with an internal capacitive holdup circuit designed to withstand micro-breaks in the input supply. If an AC voltage sag or loss occurs below standard operating thresholds, the unit maintains stable DC backplane distribution for a specific millisecond threshold, allowing the CPU to execute orderly safe-state fallback tasks before shutting down.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Guide the 1.06 lbs power module into the primary leftmost slot channel of a grounded TSX RKY subrack assembly. Push the module backward until the heavy-duty rear power pins lock square into the backplane matrix, then tighten the captive faceplate retaining screws. Maintain a minimum 50 mm clearance perimeter above and below the cooling vents to support continuous convective airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all incoming 100-240 VAC power feeds inside dedicated panel wire channels separate from low-voltage DC lines, sensor feedback loops, and data cables. Ensure the module's protective earth (PE) terminal block screw is bonded directly to the enclosure's main copper grounding bar via a thick, low-impedance conductor to safely dissipate common-mode electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45143430103155,"sku":"TSXPSY2600M","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-01_10-25-25_8f5bcb7c-4c1d-4d0f-b5da-e0db1378593e.png?v=1782876031","url":"https:\/\/www.dcssupplier.com\/products\/schneider-tsxpsy2600m-modicon-premium-power-supply-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}