{"product_id":"schneider-tsxscpcm4030-premium-connecting-cable","title":"Schneider TSXSCPCM4030 Premium Connecting Cable","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSXSCPCM4030\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXSCPCM4030\u003c\/strong\u003e Modbus Connecting Cable, operates as a dedicated hardware component for physical serial differential line connection, signal termination, and unmanaged data routing within Modicon Premium Automation platforms. The prefabricated cable assembly links serial communication cards natively at the hardware tier to transmit data packets across isolated RS422 or RS485 tap networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXSCPCM4030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg (0.35 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Physical Length\u003c\/td\u003e\n\u003ctd\u003e3 m (9.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Functional Type\u003c\/td\u003e\n\u003ctd\u003eModbus connecting cable for isolated RS422\/485 tap link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Destination Interconnect\u003c\/td\u003e\n\u003ctd\u003ePassive junction box \/ TSXSCA50 T-junction box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Compatibility Matrix\u003c\/td\u003e\n\u003ctd\u003eTSXSCP114 PCMCIA serial communication card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary\/Secondary Interface Configuration\u003c\/td\u003e\n\u003ctd\u003eFlying leads on both termination boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus, Character mode (ASCII\/Binary serial streams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight\u003c\/td\u003e\n\u003ctd\u003e225.0 g (7.94 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eGoverned by connected host module housing parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Protocol Bridging\u003c\/strong\u003e The prefabricated cable assembly functions as an impedance-matched physical layer bridge for RS422\/485 serial logic lines. By eliminating mechanical joint resistance, it channels high-speed Modbus or Character mode data frames straight into the memory registers of the TSXSCP114 PCMCIA communication card, securing uninterrupted transmission cycles parallel to central PLC processing tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Serial Topology Expansion\u003c\/strong\u003e The 3 m physical link optimizes terminal density scaling within complex networking architectures by permitting direct raw point-to-point wiring to a TSXSCA50 passive junction box. The dual-sided flying lead construction allows custom pinning field modifications, facilitating clean segment separation across multi-drop field drive configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What programmatic or electrical faults manifest if the flying leads are miswired at the passive junction box?\u003c\/p\u003e\n\u003cp\u003eA: Reversing the differential signal lines (A\/B or RX+\/RX-) prevents data packet formulation across the serial engine. This structural wiring fault causes immediate message timeouts, triggers Modbus communication error bits inside the PLC logic, and stops network synchronization tasks without damaging the physical transceiver chips.\u003c\/p\u003e\n\u003cp\u003eQ: Can the flying lead terminations be modified or spliced while the serial bus is actively polling?\u003c\/p\u003e\n\u003cp\u003eA: No, altering the wiring while active is restricted. Physically breaking or tapping into the lines causes an instantaneous open-circuit fault on the active fieldbus segment, forcing downstream variable speed drives or remote I\/O nodes into their programmed fallback safety states due to reflected waves and data corruption.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":45114990657651,"sku":"TSXSCPCM4030","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-18_17-15-21_89badfdd-8ba9-4172-8e7a-0ed6b4ac7fea.png?v=1781775657","url":"https:\/\/www.dcssupplier.com\/products\/schneider-tsxscpcm4030-premium-connecting-cable","provider":"DcsSupplier Limited","version":"1.0","type":"link"}