{"product_id":"siemens-6se6400-1pb00-0aa0-micromaster-4-profibus-module","title":"Siemens 6SE6400-1PB00-0AA0 MICROMASTER 4 PROFIBUS Module","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens 6SE6400-1PB00-0AA0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e6SE6400-1PB00-0AA0\u003c\/strong\u003e PROFIBUS Module, operates as a dedicated hardware component for fieldbus communication integration within MICROMASTER 4 drive platforms. It executes high-speed cyclic data exchange and parameter serialization natively at the drive tier to maintain inverter control metrics parallel to master control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6SE6400-1PB00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 lbs (Approx. 0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS Communication Option Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMICROMASTER 4 (MM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Frame Compatibility\u003c\/td\u003e\n\u003ctd\u003eMICROMASTER 4 FX and GX frame sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Requirement\u003c\/td\u003e\n\u003ctd\u003eMandatory deployment of 6GK1500-0EA02 specialized plug for physical mating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinuation Date\u003c\/td\u003e\n\u003ctd\u003e01.10.2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Control Routing:\u003c\/strong\u003e The option module mounts to the drive interface link, establishing direct data routing paths with the main inverter controller board. It processes control words and frequency setpoints without introducing transmission lag variations that could distort backplane bus communication velocity sync cycles during high-dynamic operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Coexistence:\u003c\/strong\u003e Operating within serial master-slave structures alongside Profinet \/ EtherNet\/IP deterministic networks, this module handles low-level torque and velocity profiles. It ensures the drive responds to cyclic master commands within designated sub-millisecond network update windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Parameter Mapping:\u003c\/strong\u003e The card enables remote configuration access to all internal drive parameters, optimizing physical I\/O density scaling requirements by replacing hardwired control lines with standard communication words. This digital integration maintains loop precision across scaling arrays without requiring external analog input cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical behavior manifests if the module experiences a complete loss of PROFIBUS cyclic communication while the drive is running?\u003c\/p\u003e\n\u003cp\u003eA: The internal watchdogs identify the network timeout, trigger a bus fault trip on the drive panel, and execute a pre-configured fail-safe state routine—such as a ramp-down or an immediate coast-to-stop—to prevent unguided motor operation.\u003c\/p\u003e\n\u003cp\u003eQ: Why does the module require the specific 6GK1500-0EA02 plug when installed on MICROMASTER 4 FX and GX frame sizes?\u003c\/p\u003e\n\u003cp\u003eA: The FX and GX frame designs feature specific physical clearance constraints and mechanical layouts around the electronics housing. The 6GK1500-0EA02 plug provides the required clearance and mechanical seating to route the communication cable without overstressing internal connectors.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":45133394739315,"sku":"6SE6400-1PB00-0AA0","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-25_10-07-36.png?v=1782353324","url":"https:\/\/www.dcssupplier.com\/products\/siemens-6se6400-1pb00-0aa0-micromaster-4-profibus-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}