{"product_id":"tsxdsy08r5a-schneider-electric-relay-output-module","title":"TSXDSY08R5A Schneider Electric Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eTSXDSY08R5A\u003c\/strong\u003e is an 8-channel discrete output module for the Schneider Electric Modicon Premium automation platform. It uses relay-protected outputs to switch AC and DC loads, supporting a range of 24 to 240 V AC and 24 to 48 V DC. The module features configurable contact arrangements, replaceable fast-blow fuses for output protection, and screw terminal connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Switching\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides eight relay outputs with a contact arrangement of \u003cstrong\u003e2 x 2 C\/O + 2 x 2 NO\u003c\/strong\u003e. This configuration combines changeover and normally open contacts, allowing the output channels to control different types of external loads according to their wiring requirements.\u003c\/p\u003e\n\u003cp\u003eThe supported output voltage ranges cover both AC and DC control circuits. Response times are less than 10 ms for activation and less than 15 ms for deactivation, which should be considered when coordinating output switching with the response requirements of connected equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connection and Rack Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXDSY08R5A uses a screw terminal block for field wiring and has a standard module format. Its current consumption is specified separately for the two rack supply voltages: 55 mA at 5 V DC and 80 mA at 24 V DC.\u003c\/p\u003e\n\u003cp\u003eThese values are relevant when calculating the power budget of a Modicon Premium rack. The module's actual power dissipation also varies with the number of energized outputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSY08R5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Platform\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type and Composition\u003c\/td\u003e\n\u003ctd\u003e2 x 2 C\/O + 2 x 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20...264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24...48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19...60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free-Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivation Response Time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeactivation Response Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eRC circuit and Ge-Mov\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e6.3 A interchangeable fast-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e6.3 A interchangeable fast-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.25 W + 0.24 W x number of outputs in state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 5 V DC\u003c\/td\u003e\n\u003ctd\u003e55 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption at 24 V DC Rack\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2000 V, 50\/60 Hz, 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e10...95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eDNV, LR, ABS, BV, RMRS, GL, RINA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, UL 508, CSA C22.2 No 142, CSA C22.2 No 213 Class I Division 2 Groups A, B, C and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110725810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Quantity\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of loads can the TSXDSY08R5A control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports AC and DC loads within its specified output voltage ranges. Its electrical durability ratings cover resistive and inductive loads under AC-12, AC-14, AC-15, DC-12 and DC-3 utilization categories. The applicable load rating must be checked for the intended switching duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TSXDSY08R5A have short-circuit protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module specifies 6.3 A interchangeable fast-blow fuses for overload and short-circuit protection. The fuse is a replaceable protective component and should be matched to the specified rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing an existing TSXDSY08R5A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the complete model number, Modicon Premium rack compatibility, field wiring, contact arrangement, AC\/DC load requirements and fuse configuration. Also check the rack power budget and the applicable electrical durability rating before replacement.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67257755369587,"sku":"TSXDSY08R5A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXDEY16A4_Cocoai_b69c4e21-53fe-4733-a780-272753658ac5.jpg?v=1795076063","url":"https:\/\/www.dcssupplier.com\/products\/tsxdsy08r5a-schneider-electric-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}