{"product_id":"westinghouse-1c31110g01-ovation-digital-input-module","title":"Westinghouse 1C31110G01 Ovation Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson 1C31110G01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1C31110G01\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete state monitoring within Ovation DCS backplane assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eGroup\/Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1C31110\u003c\/td\u003e\n\u003ctd\u003eG01\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003ctd\u003eDiscrete Digital Input Module (Standard Voltage Threshold)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1C31110\u003c\/td\u003e\n\u003ctd\u003eG02\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003ctd\u003eDiscrete Digital Input Module (Extended Voltage \/ Alternate Contact Configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31110G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWestinghouse \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eOvation DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Density\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 lbs (0.15 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation I\/O Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Channel-to-Channel Conditioning\u003c\/h3\u003e\n\u003cp\u003eDesigned for process control applications, the module integrates optical galvanic isolation across all 16 discrete input channels to prevent field electrical transients from penetrating internal logic circuits. The module filters contact bounce and line noise while validating field contact states. Internal signal-conditioning circuitry continuously processes field loop status, reporting live channel data to the controller backplane with minimal propagation delay.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1C31110G01 module be replaced while the I\/O rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping under power without causing disruption to adjacent I\/O modules on the Ovation backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be taken regarding field cable shielding during installation?\u003c\/p\u003e\n\u003cp\u003eA: Cable shields must be terminated at a single grounding point on the enclosure cabinet ground bus to prevent ground loop currents from interfering with discrete state detection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the Ovation I\/O base slot is free of dust and debris prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit board with the guide rails of the DIN-rail mounted base block.\u003c\/li\u003e\n\u003cli\u003eSlide the assembly in smoothly until the mechanical locking clip snaps into place.\u003c\/li\u003e\n\u003cli\u003eCheck field power supply levels before connecting signal lines to the termination block screw terminals.\u003c\/li\u003e\n\u003cli\u003eMaintain dedicated wire routing for field input cables, separating signal lines from high-voltage AC power lines by a minimum of 300 mm.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Westinghouse","offers":[{"title":"Default Title","offer_id":66735064252531,"sku":"1C31110G01","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1C31110G01_Cocoai_2500e775-7a1b-407f-a36c-720e92e6b028.jpg?v=1790662149","url":"https:\/\/www.dcssupplier.com\/products\/westinghouse-1c31110g01-ovation-digital-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}