{"product_id":"westinghouse-1c31206g01-ovation-module-base-assembly","title":"Westinghouse 1C31206G01 Ovation Module Base Assembly","description":"\u003cp\u003eConfigured for multi-module interconnectivity and backplane signal routing in Westinghouse Ovation control nodes, the \u003cstrong\u003eWestinghouse 1C31206G01\u003c\/strong\u003e (\u003cstrong\u003e1C31206G01\u003c\/strong\u003e Module Base Assembly) provides direct physical and electrical execution of 4-slot I\/O backplane interfacing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31206G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWestinghouse \/ Emerson Ovation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.32 lbs (0.60 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation 4-Slot Base Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e4 I\/O module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eBaseplate mounting assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eInternal deterministic backplane interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe internal printed circuit board traces within the 1C31206G01 base assembly maintain fixed backplane bus communication velocity across all 4 module slot interfaces. Designed for high-density I\/O configurations, the backplane traces isolate power distribution paths from high-speed control signal buses to prevent noise induction and signal attenuation. Physical alignment tracks guide individual I\/O electronic modules into multi-pin backplane connectors, maintaining stable structural seating and reliable low-impedance electrical connections across the localized cabinet bus network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1C31206G01 base assembly draw electrical power directly from the system power supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the assembly functions as a passive backplane housing unit. Power routing occurs through internal power traces when active I\/O modules and external power feed connectors are secured onto the base structure.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple 1C31206G01 base assemblies be daisy-chained within the same Ovation node chassis?\u003c\/p\u003e\n\u003cp\u003eA: Yes, dedicated interconnect cable buses allow multiple base assemblies to link in series, expanding total I\/O density while preserving deterministic backplane communication timing.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding precautions must be taken during base assembly installation?\u003c\/p\u003e\n\u003cp\u003eA: The metal mounting hardware must bond securely to the enclosure backpanel to ensure common reference grounding across all inserted module shields and divert high-frequency noise away from backplane signal traces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all cabinet power and field power supplies before mounting the base assembly or attaching system extension cables.\u003c\/li\u003e\n\u003cli\u003eFasten the 1C31206G01 module base to the enclosure mounting panel using appropriate hardware, ensuring a flat, torque-balanced surface alignment to avoid mechanical stress on the printed circuit backplate.\u003c\/li\u003e\n\u003cli\u003eEstablish a dedicated low-impedance bond between the baseplate grounding connection and the main panel grounding bar.\u003c\/li\u003e\n\u003cli\u003eVerify that edge connector pins and socket tracks are free of dust or debris prior to latching I\/O modules into any of the 4 slots.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Westinghouse","offers":[{"title":"Default Title","offer_id":48380153004147,"sku":"1C31206G01","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1X00014H012_Cocoai.jpg?v=1789889490","url":"https:\/\/www.dcssupplier.com\/products\/westinghouse-1c31206g01-ovation-module-base-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}