{"product_id":"westinghouse-7379a13g04-circuit-breaker-interface-cards","title":"Westinghouse 7379A13G04 Circuit Breaker Interface Cards","description":"\u003cp\u003eConfigured for power distribution and signal processing in Westinghouse WDPF and Q-Line control platforms, the \u003cstrong\u003eWESTINGHOUSE 7379A13G04\u003c\/strong\u003e (\u003cstrong\u003e7379A13G04\u003c\/strong\u003e QPA Card) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eGroup\/Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e7379A13\u003c\/td\u003e\n\u003ctd\u003eG04\u003c\/td\u003e\n\u003ctd\u003eQPA (Q-Line Power Amplifier) Circuit Card Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e7379A13G04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWESTINGHOUSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Q-Line card weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Westinghouse Q-Line card footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eQ-Line System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Type\u003c\/td\u003e\n\u003ctd\u003eQPA (Q-Line Power Amplifier) Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 7379A13G04 power amplifier interface card links local field excitation loops directly with the internal rack backplane. Built with optimized trace layouts, it supports deterministic backplane bus communication velocity and stable signal delivery across the host card cage slot allocation. Onboard filtering stages prevent supply ripple from introducing noise into adjacent digital and analog channels during real-time control operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What precautions should be taken when inserting the 7379A13G04 into the Q-Line chassis slot?\u003c\/p\u003e\n\u003cp\u003eA: Chassis power must be de-energized prior to seating or extracting the board. Align the module card edges with the rack guide channels and apply even pressure until the edge connector mates firmly with the backplane receptacle.\u003c\/p\u003e\n\u003cp\u003eQ: Can this QPA card be interchanged with other 7379A13 group suffixes?\u003c\/p\u003e\n\u003cp\u003eA: No, specific group suffixes (G04) indicate exact onboard component populations and voltage drive characteristics. Substituting a different suffix may lead to hardware mismatch or improper signal amplification levels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that system cabinet backplane power is fully isolated before installing or removing the 7379A13G04 card.\u003c\/li\u003e\n\u003cli\u003eWear an ESD grounding wrist strap attached to an unpainted metal surface of the enclosure frame to prevent electrostatic damage.\u003c\/li\u003e\n\u003cli\u003eSlide the board carefully along the card guide rails until the rear edge connector seats fully into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eFasten the faceplate retention screws to secure the card against operational vibration and ensure proper chassis grounding.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Westinghouse","offers":[{"title":"Default Title","offer_id":48380008333427,"sku":"7379A13G04","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/7379A06G02_Cocoai_cb4849e2-49cd-4e84-bfa8-e09aa1d8da0f.jpg?v=1789890718","url":"https:\/\/www.dcssupplier.com\/products\/westinghouse-7379a13g04-circuit-breaker-interface-cards","provider":"DcsSupplier Limited","version":"1.0","type":"link"}