{"product_id":"woodward-8440-1843-genset-controller","title":"Woodward 8440-1843 Genset Controller","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 8440-1843\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eeasYgen-3200-5-P2\u003c\/strong\u003e (and belonging to the \u003cstrong\u003eeasYgen-3000\u003c\/strong\u003e series platform), operates as a dedicated hardware component for complex generator set management, multi-unit load sharing, and utility paralleling applications. This panel-mounted controller provides direct physical\/electrical execution by measuring three-phase generator parameters, evaluating current scaling bounds up to 32,000 A, and executing automatic or manual engine-generator control loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-1843 (easYgen-3200-5-P2 \/ easYgen-3500-5-P2 variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard easYgen-3000 series housing mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Dimensions\u003c\/td\u003e\n\u003ctd\u003e282W x 216H x 96D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C typical industrial environment range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum of 19 W (Intrinsic Consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 measurement calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 rear housing \/ IP front panel (with screw fastening)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Current Range\u003c\/td\u003e\n\u003ctd\u003e1 to 32,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interfaces\u003c\/td\u003e\n\u003ctd\u003eIsolated relay outputs, discrete input logic mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eeasYgen-3000 Series Generator Set Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Engine-Governor Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe 8440-1843 regulates auxiliary bias lines to manage actuator loop feedback response parameters across external speed governors and automatic voltage regulators (AVR), stabilizing engine speed and terminal voltage output lines. The onboard microprocessing unit processes synchronized busbar frequencies, real-time current vectors, and generator voltage phase errors, calculating exact analog loop correction metrics to prevent system instability during load or no-load testing procedures. The software architecture runs fully configurable alarms and functional testing matrices, executing deterministic protection overrides and writing immediate active trip parameters straight to the internal memory log registers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the Remote Stop operation mode initiated on the 8440-1843 controller via discrete wiring?\u003c\/p\u003e\n\u003cp\u003eA: Remote control stop mode activates automatically the instant discrete input 9 is de-energized. Dropping the 24 VDC logic high state on this dedicated terminal causes the controller to immediately execute its programmed engine cool-down or crash-stop routine.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum electrical load power draw expected from the 8440-1843 internal logic rails?\u003c\/p\u003e\n\u003cp\u003eA: As a P2 designated model, the controller exhibits an intrinsic power consumption rating of up to 19 W maximum. Auxiliary DC power supply networks must be scaled to support this thermal dissipation limit under full backlighting and relay output loads.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":45054309171315,"sku":"8440-1843","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-14_09-18-19_16515fbb-2baf-414e-b977-0db7d192908e.png?v=1780016745","url":"https:\/\/www.dcssupplier.com\/products\/woodward-8440-1843-genset-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}