{"product_id":"woodward-9905-968-linknet-analog-input-module","title":"WOODWARD 9905-968 Linknet Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 9905-968\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e9905-968\u003c\/strong\u003e Linknet 6-Channel Analog Input Module, operates as a dedicated hardware component for localized sensor signal conditioning and data-acquisition processing within Linknet and related turbine control topologies. This slot- or panel-mounted interface module provides direct physical execution by accepting multiple concurrent 4-20 mA current loops from field transmitters, digitizing raw analog variables, and transmitting processed data streams across the industrial network backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9905-968\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.82 kg (4.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial cabinet environment baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via Linknet node network power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Loop Input\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent loop from pressure, temperature, or position sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-accuracy analog-to-digital converter (ADC) per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eLinknet Gas Turbine Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Distributed Process Control\u003c\/h3\u003e\n\u003cp\u003eThe 9905-968 regulates front-end input signals utilizing dedicated channel-to-channel isolation networks, mitigating common-mode electrical transients and ground-loop noise before data processing blocks can corrupt active sampling cycles. Each input loop runs through a dedicated low-pass filtration and scaling block to maintain maximum signal accuracy, even inside turbine cabinets with extreme electromagnetic interference (EMI). The internal processing circuits feature absolute firmware flash compatibility with upstream control processors, utilizing high-speed hardware clocks to achieve a fast sampling rate that drives updated digital data packages straight to the primary system tracking registers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the channel-to-channel isolation circuits on the 9905-968 analog input card?\u003c\/p\u003e\n\u003cp\u003eA: Isolation pathways prevent electrical field hazards—such as localized ground potential loops or high-voltage shorts on a single 4-20 mA sensor line—from spreading down adjacent measurement lines or disabling the main Linknet network processor core.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 9905-968 module process inputs from RTD or thermocouple elements directly without field transmitter units?\u003c\/p\u003e\n\u003cp\u003eA: This specific variant is calibrated strictly for 4-20 mA current loop interfaces. To connect raw RTD or thermocouple signals, an external intermediate signal conditioner or transmitter must step the sensor variable up to a standard 4-20 mA profile before it arrives at the module's terminal blocks.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":45054309236851,"sku":"9905-968","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-29_09-04-30.png?v=1780017236","url":"https:\/\/www.dcssupplier.com\/products\/woodward-9905-968-linknet-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}