{"product_id":"woodward-csc1-fi3-se-compressor-control-module","title":"Woodward CSC1-FI3-SE Compressor Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward CSC1-FI3-SE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCSC1-FI3-SE\u003c\/strong\u003e Compressor Control Module, operates as a dedicated hardware component for localized process calculation, real-time surge protection coordination, and anti-choke regulation within industrial compression platforms. Configured to withstand extreme thermal conditions, the rail-mounted logic assembly provides direct physical and data execution to govern high-velocity compressor loops across demanding plant fields.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCSC1-FI3-SE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50 kg (3.31 lbs) net assembly mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e273.6 mm x 214.1 mm x 59.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Profile\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rail mounting installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIntegrated Modbus and CAN bus network interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (-40 to +185 deg F) continuous plant limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing operational envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eController Processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Drives \u0026amp; Governor Control Loop Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV\/Hz and Field-Oriented Vector Control Coordination\u003c\/strong\u003e The compressor controller interfaces natively with variable frequency drive (VFD) tracks and guide-vane positioners. By tracking real-time line pressures and internal gas velocities, the internal microprocessing engine computes complex anti-surge margins, translating these thermodynamic vectors into direct speed commands to prevent mechanical compressor stall transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator Loop Feedback Response and Thermal Dissipation Profiles\u003c\/strong\u003e The internal logic layout enforces precise loop update times across the Modbus and CAN bus networks, allowing rapid fuel or bypass valve actuator response during quick system upset scenarios. The 1.50 kg module structure uses natural convection dissipation pathways to operate continuously within an extended -40 to +85 deg C thermal environment without causing data corruption or thermal de-rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated CAN communication bus enhance compressor loop safety compared to serial Modbus interfaces?\u003c\/p\u003e\n\u003cp\u003eA: The CAN bus link provides high-speed, deterministic data frame transport with embedded bit-error tracking and priority-based message arbitration. This low-latency network path allows the module to link concurrently with critical safety shutdown systems and primary motor governors, guaranteeing rapid valve actuation if surge parameters are breached.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation consequences if the external 24 VDC power feed experiences high voltage ripple distortion?\u003c\/p\u003e\n\u003cp\u003eA: Excessive AC ripple components on the primary 24 VDC line will bypass basic input filters and inject electrical noise into the internal analog-to-digital converter stages. This voltage disruption skew pressure transmitter data tracking loops, causing false safety alarms or unintended control valve corrections.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":45103347531891,"sku":"CSC1-FI3-SE","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-14_09-18-19_ab6d7e45-91b0-4d93-b9a5-43d67a31a39e.png?v=1781508906","url":"https:\/\/www.dcssupplier.com\/products\/woodward-csc1-fi3-se-compressor-control-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}