{"product_id":"yokogawa-7m190-ydm06-analog-input","title":"Yokogawa 7M190-YDM06 Analog Input","description":"\u003cp\u003eConfigured for high-precision signal acquisition in CENTUM CS 3000 systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa 7M190-YDM06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e7M190-YDM06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Module) provides direct physical and electrical execution of multi-sensor data processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7M190-YDM06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact DCS module form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage, current, thermocouple, RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 7M190-YDM06 is engineered to maintain signal integrity for HART-enabled field devices connected to the DCS backplane. Its internal circuitry minimizes resistance, ensuring that digital HART data superimposed on the analog loop is transmitted without attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 500 VDC isolation between channels and the backplane. This electrical separation prevents ground loops and common-mode noise propagation, which is necessary when gathering data from geographically distributed sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor thermocouple-based inputs, the module utilizes high-precision CJC circuitry to ensure that temperature measurement accuracy is maintained despite ambient heat within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe proprietary digital interface enables deterministic data exchange with the central controller, ensuring that high-resolution 16-bit analog values are processed and updated within the system's scan cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 7M190-YDM06 support module-level hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-insertion and extraction within the CENTUM CS 3000 rack; however, ensure the channel is set to \"Maintenance Mode\" in the engineering workstation before physical removal to avoid false process alarms.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input types be mixed within a single module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports channel-by-channel configuration. The specific input type (voltage, current, TC, or RTD) is defined via the system software and the physical wiring configuration at the terminal block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the module into the designated DCS I\/O rack slot. Ensure that the backplane connector is fully seated to guarantee a reliable ground bond and bus communication contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate the cable shield at the designated ground lug on the I\/O rack. A low-impedance ground connection is mandatory to ensure the efficacy of the 500 VDC isolation and to drain EMI from field-side wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain strict separation between analog signal conductors and high-voltage power lines. Use twisted-pair, shielded cabling for all thermocouple and RTD sensors to mitigate inductive noise coupling and ensure the 16-bit resolution is not compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45176225398899,"sku":"7M190-YDM06","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-15_11-25-24_3fcdb18a-d6f8-4103-a924-c9ab767720f6.png?v=1783402905","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-7m190-ydm06-analog-input","provider":"DcsSupplier Limited","version":"1.0","type":"link"}