{"product_id":"yokogawa-aat145-s03-analog-input-module","title":"Yokogawa AAT145-S03 ANALOG INPUT MODULE","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AAT145-S03 \u003c\/strong\u003eis a high-precision analog input module designed for industrial automation systems, offering reliable signal acquisition from multiple analog sensors. It supports a wide range of input types, including voltage and current signals, ensuring accurate process data collection. Moreover, its robust construction and conformal coating provide long-term reliability even in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis module integrates seamlessly with Yokogawa FIO and CENTUM VP systems, facilitating scalable and flexible system expansion. Therefore, engineers can deploy the AAT145-S03 confidently for critical process control applications, ensuring continuous operation. In addition, its standardized connections and compact design simplify installation and maintenance, reducing system downtime.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAT145-S03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, 0–10 V, ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling\/Scan Period\u003c\/td\u003e\n\u003ctd\u003e100 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Detection\u003c\/td\u003e\n\u003ctd\u003eOpen\/short circuit detection per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt;10 kΩ; Current: 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd\u003e5–95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eFIO baseplate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, FIO subsystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA (region dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-end=\"2930\" data-start=\"2907\"\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003eFAQ\u003cstrong style=\"font-size: 0.875rem;\" data-end=\"2930\" data-start=\"2907\"\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eA1: What signal types does the AAT145-S03 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports 0–20 mA, 4–20 mA, 0–10 V, and ±10 V analog signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2: Can it detect faults in analog inputs?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, each channel includes open and short circuit detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3: Is the module compatible with Yokogawa control systems?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it works with CENTUM VP and FIO subsystems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4: Is it suitable for harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it features conformal coating and robust construction for reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA5: How is the module installed?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt can be mounted on DIN rails or FIO baseplates for convenient integration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44122330988659,"sku":"AAT145-S03","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/YokogawaAAT145-S03ANALOGINPUTMODULE.jpg?v=1764638560","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-aat145-s03-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}