{"product_id":"yokogawa-adv561-p00-digital-output-module-1","title":"Yokogawa ADV561-P00 Digital Output Module","description":"\u003cp\u003eConfigured for high-density digital signal switching and pulse execution in CENTUM VP platforms, the \u003cstrong\u003eYokogawa ADV561-P00\u003c\/strong\u003e (\u003cstrong\u003eADV561\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eIncludes pulse width output function and time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ci\u003eNote: Suffix position 2 option codes include \"5\" (Without status display; no explosion protection) or \"E\" (Without status display; with explosion protection). Suffix position 4 option codes include \"0\" (Basic type) or \"4\" (With ISA Standard G3 option).\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV561-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP I\/O card slot dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA (5 VDC backplane), 120 mA (External power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 100 mA (Voltage range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e2 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leak Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Signal to System)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e600 V AC for 1 minute (common minus side every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms or less (status output), 10 ms or less (mixed status\/pulse outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Output\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s (resolution 8 ms, ON\/OFF delay up to 1 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime-Proportioning Output\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDedicated cable (AKB397) or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel isolation networks designed to prevent parasitic ground loops across large digital output banks. Operating within standard DCS I\/O racks, the galvanically isolated output paths protect sensitive backplane electronics from field-side voltage transients up to 2 kV AC. Cold junction compensation and precise current loop regulation across neighboring analog and digital channels ensure noise immunity and stable signal execution across high-density field interface wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What precautions must be taken regarding common terminals during field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Common negative (-) terminals are grouped every 16 channels. The isolation withstand voltage between distinct commons is rated at 600 V AC for 1 minute; wiring across different commons must not exceed this potential difference.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ADV561-P00 handle high-speed pulse width generation without host CPU overhead?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The onboard hardware executes pulse width timing from 8 ms to 7200 s with an 8 ms resolution directly at the module level, relieving the central control station CPU of high-frequency timing tasks.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the external 24 VDC power supply prior to connecting or disconnecting the AKB397 or MIL connector cables to prevent pin arcing.\u003c\/li\u003e\n\u003cli\u003eEnsure field cable shields are bonded to protective earth at a single point to prevent high-frequency noise injection into the current sink channels.\u003c\/li\u003e\n\u003cli\u003eObserve the total current limits per 16-channel common group to ensure backplane trace temperature limits are not exceeded during continuous output operation.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC field supply stays within the required 20.4 to 26.4 VDC operating window under full load conditions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45368434983027,"sku":"ADV561-P00","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ATA4S-00_1.jpg?v=1786946411","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-adv561-p00-digital-output-module-1","provider":"DcsSupplier Limited","version":"1.0","type":"link"}