{"product_id":"yokogawa-afv30d-s41262-control-unit","title":"Yokogawa AFV30D-S41262 Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV30D-A41262\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAFV30D-A41262\u003c\/strong\u003e Field Control Unit, operates as a dedicated hardware component for Vnet\/IP communication and field I\/O processing within CENTUM VP control system platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFV30D\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit (19-inch rack mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-A\u003c\/td\u003e\n\u003ctd\u003eStandard type (for CP471 processor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP, dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eR6.01 or later version support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFV30D-A41262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e207 mm x 482.6 mm x 465.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol\u003c\/strong\u003e: The unit manages FIO communication, supporting pass-through of HART protocol data from field instrumentation to the control function for asset management and process monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity\u003c\/strong\u003e: Integration with the field control station allows for high-speed deterministic data exchange, supporting standardized digital bus communications within the CENTUM VP architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation\u003c\/strong\u003e: The modular design ensures electrical isolation between internal processing boards and field I\/O segments, maintaining signal integrity and protection against common-mode noise across the I\/O bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC)\u003c\/strong\u003e: The unit interfaces with associated FIO modules that provide precise thermal compensation for thermocouple-based temperature measurement inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the unit support dual-redundant processor configurations for continuous operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The duplex architecture employs two parallel processor modules (CP471) that continuously synchronize data, ensuring seamless failover without interrupting control execution.\u003c\/p\u003e\n\u003cp\u003eQ: What are the cabinet installation requirements for compliance standards?\u003c\/p\u003e\n\u003cp\u003eA: To meet safety and EMC standards, the unit must be installed securely within a keyed metallic cabinet.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the 19-inch rack unit securely inside a grounded, keyed metallic cabinet to satisfy electromagnetic compatibility and safety compliance requirements.\u003c\/li\u003e\n\u003cli\u003eTerminate the 220 - 240 V AC power supply to the designated terminals while ensuring proper earth grounding to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eRoute Vnet\/IP communication cabling separately from high-voltage power paths and variable frequency drives to prevent interference and maintain deterministic communication rates.\u003c\/li\u003e\n\u003cli\u003eVerify that module chassis and I\/O shield grounds are tightly secured to the cabinet grounding bar to preserve signal integrity and channel isolation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45270665101427,"sku":"AFV30D-S41262","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-09_16-40-23_973a378d-607f-4b9d-bab1-6a6ec8627cce.png?v=1784710660","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-afv30d-s41262-control-unit","provider":"DcsSupplier Limited","version":"1.0","type":"link"}