{"product_id":"yokogawa-anb10d-410-cu2n-centum-vp-analog-input","title":"Yokogawa ANB10D-410\/CU2N CENTUM VP Analog Input","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-415\/CU2N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D-410\/CU2N\u003c\/strong\u003e ESB Bus Node Units, operates as a dedicated hardware component for distributed node communication and optical\/electrical ESB bus interfacing within CENTUM VP control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-415\/CU2N (Updated from ANB10D-410\/CU2N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack mountable node unit housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 50 VA (24 VDC \/ 100-120 VAC depending on power supply module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Fieldbus Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB Bus Communication Rate\u003c\/strong\u003e: Executes high-speed deterministic data exchange across node units utilizing proprietary ESB bus protocol layers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: Implements galvanic isolation rated at 1500 VAC for 1 minute between field terminals and internal system power planes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJC and Signal Conditioning\u003c\/strong\u003e: Incorporates real-time cold junction compensation (CJC) circuits for thermocouple inputs and supports HART pass-through communication for smart field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e: Fully compatible with dual-redundant ESB bus interface card configurations to ensure uninterrupted control network availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ANB10D-415\/CU2N node unit support hot-swapping of internal power supply and communication modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the node unit architecture supports hot-swapping of redundant power supply modules and node adapter modules under operational state without disrupting rack backplane bus integrity.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable physical distance supported by the ESB bus connection from the local node to the main control unit?\u003c\/p\u003e\n\u003cp\u003eA: Standard ESB bus configurations support cable lengths up to 10 meters per segment, extendable via optical bus repeater modules when required by facility layout constraints.\u003c\/p\u003e\n\u003cp\u003eQ: How does the updated ANB10D-415\/CU2N differ from the previous ANB10D-410\/CU2N revision?\u003c\/p\u003e\n\u003cp\u003eA: The ANB10D-415\/CU2N incorporates upgraded firmware flash compatibility and improved backplane bus driver components to enhance noise immunity and transient suppression.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper grounding of the 19-inch rack chassis to the facility protective earth (PE) busbar using copper conductors with a minimum cross-sectional area of 2.0 mm2.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum vertical clearance of 50 mm above and below the enclosure housing to allow adequate thermal convection across heat dissipation profiles.\u003c\/li\u003e\n\u003cli\u003eRoute shielded communication cables and power supply wiring through dedicated metallic conduits to prevent electromagnetic interference (EMI) coupling into low-level analog circuits.\u003c\/li\u003e\n\u003cli\u003eVerify terminal screw torque values between 0.8 Nm and 1.2 Nm to secure physical wiring connections and prevent high-resistance contact faults.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45279442370675,"sku":"ANB10D-410\/CU2N","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/AFS30D_1_245e8d7d-3641-41d8-ac9b-62d528c1d242.jpg?v=1784877547","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-anb10d-410-cu2n-centum-vp-analog-input","provider":"DcsSupplier Limited","version":"1.0","type":"link"}