{"product_id":"yokogawa-f3xd16-3f-dc-input-module","title":"Yokogawa F3XD16-3F DC Input Module","description":"\u003cp\u003eConfigured for discrete signal acquisition in FA-M3 control platforms, the \u003cstrong\u003eYokogawa F3XD16-3F\u003c\/strong\u003e (\u003cstrong\u003eF3XD16-3F\u003c\/strong\u003e) DC Input Module provides direct physical\/electrical execution of 16-channel voltage detection, photocoupler isolation, and backplane-to-field signal framing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3XD16-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e65 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 independent input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa Industrial Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The module interfaces with the FA-M3 backplane to report state changes to the CPU. This bus velocity is mandatory to ensure that the input status is updated within the deterministic scan window required for high-speed process interlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e The module enables field-side discrete signals to be mapped into the FA-M3 network architecture. This facilitates the transmission of sensor status data across deterministic network segments, which is mandatory for maintaining real-time visibility of field device states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The module incorporates 16 high-density input channels within a single slot. This scaling is mandatory to maximize input point capacity in control cabinets where space is limited, while maintaining electrical separation between individual signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The internal logic of the F3XD16-3F is designed for integration with diverse FA-M3 controller firmware revisions, ensuring operational stability across updated system software environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3XD16-3F support hot-swapping within the FA-M3 rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be isolated from the rack and the field-side input signals de-energized before physical removal. Hot-swapping risks electrical transients that can damage the internal photocoupler isolation barriers or the rack backplane pins.\u003c\/p\u003e\n\u003cp\u003eQ: Is the input stage compatible with both current-sourcing and current-sinking field devices?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is engineered for flexible field-side wiring, supporting both source and sink configurations. Always verify the common-rail polarity during field installation, as incorrect wiring will prevent the photocoupler from triggering, resulting in a constant \"Off\" state for the affected input channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module firmly into the FA-M3 rack and secure the front-face retention screws. A rigid installation is mandatory to maintain stable backplane contact and prevent vibration-induced signal flickering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module’s chassis to the cabinet’s main safety earth bus. A low-impedance ground connection is mandatory to ensure the efficacy of the photocoupler isolation and to protect the module from transient surges on the 24 VDC input lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate 24 VDC field inputs using shielded, twisted-pair cabling. Maintain a separation of at least 150 mm from high-voltage power conduits to prevent inductive noise injection, which is mandatory to protect the internal photocoupler circuits from spurious switching or damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45191851016307,"sku":"F3XD16-3F","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-08_15-42-01_0607078c-745a-4cbe-9b2f-207e98b0074c.png?v=1783568400","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-f3xd16-3f-dc-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}