{"product_id":"yokogawa-s9341f","title":"Yokogawa S9341FA Enhanced System Bus Terminator Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa S9341FA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS9341FA\u003c\/strong\u003e Terminator Module for ESB Bus, operates as a dedicated hardware component for impedance matching, bus signal absorption, and electrical transmission line stabilization within Yokogawa CENTUM distributed control system networks. The passive end-of-line component provides direct physical execution to maintain network communication layout integrity across high-speed system extension rails.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS9341FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg net component mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e438 mm x 133 mm x 425 mm (unpacked structural boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C (14 to +131 deg F) continuous plant limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C (-4 to +158 deg F) climate preservation boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Application\u003c\/td\u003e\n\u003ctd\u003eYokogawa Enhanced System Bus (ESB) communication lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Profile\u003c\/td\u003e\n\u003ctd\u003ePassive electrical end-of-line matching network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBus Terminator Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Rails\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/strong\u003e While this hardware module is deployed directly on the high-speed digital ESB backplane trunk line rather than processing analog instrumentation fields, its noise-suppression characteristics protect adjacent 4-20 mA HART loop networks. By binding the high-frequency digital square waves to a hardwired impedance baseline, the terminator prevents electrical noise from radiating out of the bus cables and into sensitive analog input\/output card wireways.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Reflection Suppression and Bus Transmission Pathways\u003c\/strong\u003e The ESB lines operate at elevated clock frequencies to move process variables between the main controller node and remote I\/O extension chassis. The module matches the characteristic impedance of the communication cable precisely at the final physical node. This absorption layout eliminates destructive voltage wave echoes and signal reflections within the data transmission pathways, keeping data frame transitions sharp and error-free.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Why is a passive terminator module mandatory at the final node of the Enhanced System Bus?\u003c\/p\u003e\n\u003cp\u003eA: High-frequency digital signals traveling down an unterminated communication bus encounter an abrupt impedance change at the open end of the cable. This boundary condition forces a portion of the signal energy to reflect backward along the copper pairs, distorting incoming data packets, corrupting message frames, and triggering communication timeout faults inside the main DCS processor.\u003c\/p\u003e\n\u003cp\u003eQ: Does this passive 0.30 kg module draw any operating current from the backplane logic supply rail?\u003c\/p\u003e\n\u003cp\u003eA: No, the module functions as a purely passive network matching matrix consisting of configured resistor networks. It draws zero active operating current from the system backplane logic power supply, acting entirely as a passive load to absorb and dissipate transmission line signal energy safely.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45103265775731,"sku":"S9341FA","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-15_111-19-36_ebc1cb74-ea7e-4a95-a3a8-ca8dc32c7e79.png?v=1781508018","url":"https:\/\/www.dcssupplier.com\/products\/yokogawa-s9341f","provider":"DcsSupplier Limited","version":"1.0","type":"link"}